1-6610115-1 Tyco Electronics, 1-6610115-1 Datasheet
![CONN 1X4 MAG45 MOD GRN/GRN PCB](/photos/32/18/321858/pr1610003_sml.jpg)
1-6610115-1
Specifications of 1-6610115-1
Related parts for 1-6610115-1
1-6610115-1 Summary of contents
Page 1
... This specification covers performance, tests and quality requirements for the Tyco Electronics Mag45* Modular Jacks with Integrated Magnetics. 1.2. Qualification When tests are performed on the subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was completed on 20Jun00 ...
Page 2
... Product Codes for this product family are H363, H364, H365 and H366 3.5. Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions per EIA-364. 3.6. Test Requirements and Procedures Summary Test Description Examination of product ...
Page 3
... Measure force necessary to mate specimens at a maximum rate of 12.7 mm [.5 in] per minute. EIA-364-13B. Measure force necessary to unmate specimens at a maximum rate of 12.7 mm [.5 in] per minute. EIA-364-4. Measure and record normal force generated at any given deflection level within the normal operating range with an FCC compliant modular plug ...
Page 4
... Class IIA for 10 days. Subject mated and mounted specimens to 2 hours at each of the following temperatures: -5, 25, 55 and 75 ± MIL-STD-810, Method 507.3. Subject mated and mounted specimens to 10 cycles (10 days) between 30 and ± RH. EIA-364-26, Test Condition B. Subject specimens to 5% spray for 48 hours. / ...
Page 5
... Specimen Selection Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test group 1 shall consist of 16 specimens. Test groups 2 and 3 shall each consist of 1 specimen. Test group 4 shall consist of 45 specimens. B. Test Sequence Qualification inspection shall be verified by testing specimens as specified in Figure 2. ...
Page 6
... Acceptance Acceptance is based on verification that the product meets the requirements of Figure 1. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal ...
Page 7
... Rev B 108-2100 ...