EVT307-5DZ-01F-Q SMC Corporation of America, EVT307-5DZ-01F-Q Datasheet - Page 16

no-image

EVT307-5DZ-01F-Q

Manufacturer Part Number
EVT307-5DZ-01F-Q
Description
VALVE, 1/8 PORT, 24VDC
Manufacturer
SMC Corporation of America
Datasheet

Specifications of EVT307-5DZ-01F-Q

Supply Voltage Max
24VDC
Operating Pressure Psi Max
0.9MPa
Operating Pressure Min
0MPa
Operating Temperature Range
0°C To +50°C
Svhc
Bis (2-ethyl(hexyl)phthalate) (DEHP) (15-Dec-2010)
Connection
RoHS Compliant
Connection Size
0.125"
Operating Pressure Max
0.9MPa
Rohs Compliant
NA
Valve Type
Poppet
VT325
Option Specifications
1.For vacuum
In contrast to the standard product, this vacuum
specification valve has less air leakage at low pres-
sures, a feature that should be taken into considera-
tion when using this valve for vacuum applications.
1)Because this valve leaks air, it cannot be
2.Manual override with lock
1) Using a screwdriver, push the manual override button that is
located in the head portion of the solenoid valve in order to direc-
try push the spool valve downward, thus causing the valve to
switch.
2) With the button remaining pushed down, turn it approximate-
ly 90° clockwise or counterclockwise to maintain the manual
override locked state.
3) To revert to the original state, keep the button pushed down
and turn it approximately 90° clockwise or counterclockwise.
1.The bottom of the solenoid valve has a breather
2. Take proper measures to prevent dust or foreign mat-
2.5-16
Pressure range
Be sure to read before handling.
Refer to p.0-33 to 0-36 for Safety
Instructions and common precautions.
Ordinarily, when the solenoid valve is mounted on
hole for the main valve. Take proper measures
to prevent this hole from being blocked as this
will lead to a malfunction.
a metal surface, it can breathe through the
breather hole, via the breather groove, However, in
particular, if the surface to be mounted is made of
rubber, the rubber could deform and block the
hole.
used for maintaining a vacuum (or pres-
sure) in a pressure vessel.
ter from entering through unused ports.
The grommet portion contains a breather hole for the
core. Take proper measures to prevent dust or for-
eign matter from accumulating in this area.
Caution
Caution
Precaution
–101.2kPa to 0.1MPa
Construction
Operation principles
<De-energized>
The spool e is pushed upward by the
force of the spring r and the air passage
between port x and port c is opened and
port z is blocked.
Air flow direction: z
Parts list
1. How to wire
1) Loosen the fix screw and pull off the connector from
2) Make sure to pull out the retaining screw before
3) Following the wiring procedure, properly connect the
4) As a rule, wires are connected to the terminals using
Wiring figure
Single solenoid 1
2. Change of electrical entry
Once the terminal cover is separated from
the terminal block, it can be rotated in any
direction (4 directions, each 90°) to change
the orientation of the electrical entry.
Flow rate
Refer to p.0-36 for flow rate calculation.
No.
q
w
e
How to Use DIN Connector
the pin plug.
inserting a screwdriver into the groove at the lower
portion of the terminal board. Then, push the screw-
driver up to separate the terminal board and the ter-
minal cover.
wires to the specified terminals.
crimp-style terminals. Therefore, select crimp-style
terminals that do not overstrain the terminal hardware.
Spool valve
Description
Cover
Body
De-energized
Pin plug
Aluminum, NBR
Block, x
Material
ADC
ADC
Platinum silver
Platinum silver
c
Notes
<Energized>
When the coil y is energized the plunger
u is pulled down depressing the spool e
via the overtravel assembly i and the air
passage between port z and port x is
opened and port c is blocked.
Air flow direction: z
3. Caution
To insert the connector into the pin plug or
to pull it out, do so as vertically as possible,
without tilting.
4. Applicable cable
Cord external: ø6 to ø12
Note: For those with external measure
5. Applicable crimp-style terminals
The maximun size for the round terminal is
1.25mm -3.5 and for the Y terminal is
1.25mm -4.
ments of ø9 to ø12, remove the inner
portion of the ground gasket before
use.
2
2
Energized
x, c
Block

Related parts for EVT307-5DZ-01F-Q