V45450-1 VEEDER ROOT, V45450-1 Datasheet - Page 121

Multifunction Counter

V45450-1

Manufacturer Part Number
V45450-1
Description
Multifunction Counter
Manufacturer
VEEDER ROOT
Type
Counterr
Datasheets

Specifications of V45450-1

No. Of Digits / Alpha
4
Digit Height
10mm
Counting Speed
10kHz
Operating Temperature Range
0°C To +55°C
Character Size
10mm
Panel Cutout Width
1.77"
Connection Type
Screw
Counter Type
Predetermining
Cut Out, Panel
1/16 DIN
Dimensions
1.89"L×4.33"W×1.89"H
Display Digit Height
10mm (Top Display), 7mm (Bottom Display)
Display Type
LED
Frequency, Operating
50⁄60 Hz
Function
Counter
Input Type
NPN
Mounting Type
Panel
Number Of Digits
6
Primary Type
Electronic
Standards
UL and cUL Recognized, CE Marked
Temperature, Operating, Range
0 to +50 °C
Terminal Type
Screw Terminal
Termination
Screw Terminal
Voltage, Supply
90 to 264 VAC
Weight
7 Oz.
Input Signals Accepted From A Variety Of Sources
Dry Contact, PNP or NPN Sensors, Encoders
Lead Free Status / RoHS Status
na
OUTPUT OPERATING MODES
DPDT - OFF Time First
DPDT - ON Time First
Overlapping Intervals
MOUNTING
The SX110 timer uses two removable mounting clips with adjustable screws to mount the enclosure in a panel as shown below.
ORDERING INFORMATION
Both outputs are energized together. The OFF time defined by
Setpoint 1 (SEt1) occurs first.
Both outputs are energized together. The ON time defined by
Setpoint 1 (SEt1) occurs first.
Output 1 is ON first. Output 2 is normally energized at the end of the
Output 1 timing interval. The Output 2 timing interval can be
programmed to begin before the end of the Output 1 interval by
using Setpoint 3 (SEt3). Setpoint 3 is the amount of time before the
end of the Output 1 interval that the Output 2 interval is started. In
repeat operation, Output 1 is energized again at the end of the
Output 2 interval.
OUTPUT 2
OUTPUT 1
OUTPUT 2
OUTPUT 1
OUTPUT 1
OUTPUT 2
and
and
(75.69)
2.98
SET 1
SET 1
OUTPUT TYPE
(75.69)
SET 1
2.98
Sym.
10
SET 3
SET 2
SET 2
SET 2
Relay Output
Description
SET 1
SET 1
SET 2
SET 2
SX1
PANEL CUTOUT
SQUARE
2.72
(68
+0.7
-0.0
+0.028
-0.000
)
10
Non-Overlapping Intervals
TERMINAL ASSIGNMENTS
Terminals 6, 7, and 11 are not used on the SX110 timer.
(5.84)
0.23
Output 1 is ON first. Output 2 is normally energized at the end of the
Output 1 timing interval. The Output 2 timing interval can be pro-
grammed to begin a delay or dwell period after the end of the Output 1
interval by using Setpoint 3 (SEt3). Setpoint 3 is the amount of time
after the end of the Output 1 interval that the Output 2 interval is started.
In repeat operation, the Setpoint 3 dwell period also occurs after the
Output 2 interval and before the Output 1 interval repeats.
OUTPUT 2
OUTPUT 1
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
A6
yy
yy
yy
yy
VOLTAGE & FREQUENCY
yyy
yyy
yyy yy
OUTPUT 1
Sym.
yy
A6
PANEL THICKNESS (STEEL)
0.125 – 0.313 (3.125 – 7.825)
SET 1
120 VAC, 50/60 Hz
Description
(127.0)
SET 3
5.00
SET 2
OUTPUT 2
OFF
ON
1
SET 3
SWITCH
2
3
4
0.50 REQUIRED
FOR WIRING
5
6
7
8
5.27
T
O
T
A
Z
N
G
L
I
I
E
L
E
C
T
R
O
N
C
I
5
M
R
T
E
S
I

Related parts for V45450-1