0195316-051 VEEDER ROOT, 0195316-051 Datasheet - Page 126

Counter Display Panel

0195316-051

Manufacturer Part Number
0195316-051
Description
Counter Display Panel
Manufacturer
VEEDER ROOT
Datasheet

Specifications of 0195316-051

No. Of Digits / Alpha
6
Digit Height
8.8mm
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
5.32
The CX200 is a microprocessor based timer/counter housed in a
standard 15 terminal CYCL-FLEX
operation, time range, and standard or reverse start operation is
selected by 7 miniature rocker switches located inside the unit housing.
Time or count setpoints are entered into the unit using a sealed
membrane keypad on the front of the unit. Each digit in the setpoint is
individually increased or decreased by pressing the appropriate keypad
switch. Time or count setpoint and progress is displayed on the front of
the unit by a 4 1/2 digit liquid crystal display with .5 inch digits. Time or
count subtracts from the setpoint and the output changes state at zero.
Operational mode annunicators also appear in the display area on the
front of the unit. The mode annunciator flashes when the unit is timing
or counting.
Five time ranges from 19.999 sec. to 199 hrs.: 59 min.
Two count rates - accept and display counts from 1 to 19999
Two relay outputs - socket mounted for easy replacement
Two form C instantaneous contacts and two form C programmed
contacts
N.O. solid state MOSFET, delayed action switch rated at 1 ampere
continuous load current, 0-264 VAC 50/60 Hz or DC
Ideal output for switching low level signals and high voltage loads
due to MOSFET output's ON resistance of 0.5 ohm and very low
OFF leakage
Programmed outputs operate in one of four load sequences; OOX,
OXO, OOX with pulse output, and OOX pulse output with repeat
cycle operation
Standard start is defined as ON delay reset timer or counter
For standard start units, timer/counter resets on power failure
Reverse start or OFF delay units will not reset on power failure and
will continue cycle when power is restored
Non-volatile memory data retention
EAGLE SIGNAL
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
®
plug-in case. Time or count
brand
CX200 Microprocessor Timer/Counter
SPECIFICATIONS
Time/Count Ranges:
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
Time Inhibit/Count Line Voltage/Frequency:
Setting Accuracy: Time:
Repeat Accuracy:
Reset Time: 30 ms following voltage removal from simulated clutch input
Power on Response: 300 ms maximum after voltage applied to terminal 11
Operating Temperature: +32° to +140°F (0° to +60°C)
Output Rating: Relay: 10 amp (resistive), 120 VAC
Vibration: Unit function is unaffected by 2.5
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
Agency Approvals: UL Recognition E96337
B6 - 240 VAC, 50/60 Hz
K6 - 208 VAC, 50/60 Hz
A6 - 120 VAC 50/60 Hz
B6 - 240 VAC 50/60 Hz
K6 - 208 VAC 50/60 Hz
Count: 100%
Time:
Count: 100%
(CR1)
Mechanical Life: 20 million operations
Electrical Life: contingent upon controlled load
Solid State: 1 amp, 0-264 VAC, VDC
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
CSA Certification LR26861
0.001% of setting or 35 ms, whichever is larger (0° to 60°C)
Sym.
1
2
3
4
5
6
7
Microprocessor based
solid state timer/
counter... housed in
CYCL-FLEX
199 Min.: 59 Sec.
199 Hr.: 59 Min.
Maximum
199.99 Sec.
1999.9 Sec.
19.999 Sec.
19999 Cts.
19999 Cts.
Range
0.1% or 50 ms, whichever is larger (0° to 60°C)
®
Minimum
.001 Sec.
Setting
.01 Sec.
.1 Sec.
1 Sec.
1 Min.
1 Ct.
1 Ct.
case
G
sinusoidal vibration magni-
®
5000/Min. AC
500/Min. AC.
RECOGNIZED
Count
Rate
CERTIFIED
®

Related parts for 0195316-051