OPERATING MODES
On-Delay
Timing begins on the leading
edge of the start input. The
output will activate at the
completion of the preset time
(T) and will remain active until
the reset signal is applied or
power is interrupted.* For
B856-511, the instantaneous
output will activate upon the
start signal and will remain
active until the reset signal is
applied or power is
interrupted.*
Off-Delay
The output is activated at the
leading edge of the start signal.
Timing begins on the trailing edge.
The output will remain active until
the preset time (T) has elapsed or
power is interrupted.* R eapplying
the start signal before T has
elapsed will reset the time value.
The reset input is not used.
Interval 1
On the leading of the start input,
the output is activated and timing
begins. The output will remain
active until the preset time (T) has
elapsed or power is interrupted.*
Removal of the start signal will
also cause the ouput to be
deactivated and the time value
reset. The reset input is not used.
Interval 2
On the leading of the start input,
the output is activated and timing
begins. The output will remain
active until the preset time (T) has
elapsed or power is interrupted.*
The reset input is not used.
Reapplying the start signal has no
effect unless the cycle has
completed.
Repeat Cycle
Timing begins on the leading edge
of the start input. A cycle is
initiated where the output will be
OFF for the preset time (T), then
ON for the preset time. This cycle
will continue until a reset signal
is applied or power is
interrupted.* The unit can also
be programmed for the timing
sequence to begin with an ON
cycle.
Delay/Interval
The delay cycle begins upon
application of the start signal.
The output will activate at the
completion of the preset time
(T1). Upon activation of the
output, the Interval cycle will
begin. The output will be
deactivated at the end of the
Interval time (T2). T1 is the
primary preset value. T2 is
settable from 0.1 to 999.9
seconds. The timing sequence
and output can also be reset
through the reset input or
interruption of power.*
Instant.
Output
Power
Start
Output
Reset
Power
Start
Output
Power
Start
Power
Start
Output
Start
Output
Output
Reset
Power
Power
Start
Output
Reset
* The Power Reset parameter can be set so that a
timing sequence will not be reset upon power
interruption but instead continue on when power is
restored.
T
T
T
Repeat Cycle
T
T
T
T
1
T
T
2
T
T
T
ORDERING INFORMATION
48mm
Description
Multi-Function (11 Pin) Timer
As Above w/Instant Contacts
Multi-Function (8 Pin) Timer
*For Drop-In Replacement of LX260 DC Version, Order B856-502
B856-500 & -511:
B856-501:
Dimensions:
Connections
Start
11 Pin Socket
11 Pin Socket - Outward
8 Pin Socket
8 Pin Socket - Outward
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
instantaneous contacts
For the -511 version,
B856-500 & -511
3
4
Pins 1, 3, 4 are the
2
Facing Terminals
Facing Terminals
EAGLE SIGNAL
5
1
Power
48mm
6
11
Reset
7
10
8
9
Accessories
8mm
66mm
Reset
* 24–240 VAC
B856-501
3
2
24 VDC
Model
B856-500
B856-511
B856-501*
60SR3P06
PBT-03172
60SR2P06
PBT-03155
15mm
4
1
or
Power*
Start
5
8
6
7
+
5.17
T
O
T
A
Z
N
G
L
I
I
E
L
E
C
T
R
O
N
C
I
5
M
R
T
E
S
I

Related parts for 0195316-051