BD40 CARLO GAVAZZI, BD40 Datasheet - Page 5

METER, 4DIGIT, MULTICOLOUR, UDM40

BD40

Manufacturer Part Number
BD40
Description
METER, 4DIGIT, MULTICOLOUR, UDM40
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of BD40

Accuracy
0.1% RDG
Current Measuring Range Dc
200
Display Technology
LED
Ip/nema Rating
IP67
No. Of Characters
4
No. Of Digits / Alpha
4
Resistance Measuring Range
20 To 20k
Supply Current
5A
Svhc
No SVHC (15-Dec-2010)
Current Range Dc
200

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BD40
Manufacturer:
TYCO
Quantity:
37 504
Part Number:
BD400
Manufacturer:
ST
0
Part Number:
BD401
Manufacturer:
ST
0
Part Number:
BD402
Manufacturer:
ST
0
Part Number:
BD403
Manufacturer:
ST
0
Part Number:
BD404
Manufacturer:
ST
0
Specifications are subject to change without notice
Software functions
Min / Max storage
Password
Measurement selection
Integration time selection
Scaling factors
Diagnostics
Burn-out:
General Specifications
Operating
temperature
Storage
temperature
Insulation reference
voltage
Insulation
Dielectric strength
Rejection
EMC
UDM40
NMRR
CMRR
Operating mode
Electrical range
Decimal point position
Displayed range of the variable Programmable within the
1st level
2nd level
Automatic storage
(in the EEPROM) of the
minimum and maximum
measured value from the
previous memory reset
Numeric code max 4 dgt
2 levels of data protection.
0 to 4999 completly protected.
5000 to 9999 access to
programming is protected .
Alarm set-points are directly
programmable from the
measuring mode.
Depending on the module:
measuring range and type of
probe (resistance, RTD
thermoresistance, TC
thermocouple) or measuring
type (TRMS or DC).
Automatic or from 100.0 to
999.9 ms only in the current
and voltage measurement.
Electrical scale compression,
displayed scale
compression/expansion
(max. 2 without filter, up to
10 with filter)
Programmable within the
whole measuring range
Programmable within the
display range
display range
The display flashes when the
limits of the display range
are exceeded and the data
are updated up to 20%
of the rated display range.
Only temperature inputs
0° to 50°C (32° to 122°F)
(H.R. < 90% non-condensing)
-10° to 60°C (14° to 140°F)
(H.R. < 90% non-condensing)
300 V
(500V input)
See table “Insulation between
inputs and outputs”
4000 V
40 dB, 40 to 60 Hz
100 dB, 40 to 60 Hz
EN61000-6-2, IEC61000-6-2
EN61000-6-3, IEC61000-6-3
RMS
RMS
to ground
for 1 minute
UDM40DS 040706
Safety Standards
Connections
Housing
Protection degree
Weight
Approvals
Digital filter
Scaling
Linearization
UdmSoft
Safety
Wire section
Dimensions
Material
Filter operating range
Filtering coefficient
Points
Input range
Output range
TC
RTD
EN 61010-1, IEC 61010-1
Screw type
Max 2.5mm
1/8 DIN, 48 x 96 x 105 mm
PC-ABS,
self-extinguishing: UL 94 V-0
Front: IP67, NEMA4x
Connections: IP20
520 g approx (included all
modules and packing)
CE, UR, CSA
Opening of probe’s
connection: EEE indication
Opening of probe’s
connection: EEE indication
probe’s short circuit:
-EEE indication.
0 to 9999
1 to 32
Selection of min value
of the input range.
Selection of max value of
the input range.
Selection of decimal point
position.
Selection of min
display value.
Selection of max display
value.
Up to 16
Selectable by every
single point
Selectable by every
single point
Software for
programming UDM40
by means of PC (Windows 95,
98se, ME, XP) by means of
serial port RS485 and
relevant connection cable.
The software is available in
English, Spanish, Italian,
German, French. See also
“Programming of
UDM40 by means of PC” .
2
5