8536SBO2V02H20S SQUARE D, 8536SBO2V02H20S Datasheet - Page 24

Magnetic Motor Starter

8536SBO2V02H20S

Manufacturer Part Number
8536SBO2V02H20S
Description
Magnetic Motor Starter
Manufacturer
SQUARE D
Datasheets

Specifications of 8536SBO2V02H20S

No. Of Phases
Three
Power Rating
5hp
Current Rating
18A
Peak Reflow Compatible (260 C)
No
Supply Voltage Max
460VAC
Control Voltage Max
120V
Leaded Process Compatible
No
Switch Function
3PST
Current, Rating
18 A
Enclosure Type
Open
Horse Power Rating
3 @ 230 VAC, 5 @ 480 VAC
Relay Type
Contactor
Standards
UL Listed File E78351 CCN NLDX - CSA Certified File LR60905 Class 3211 04
Voltage, Coil
24 VAC
Supply Voltage Range
110VAC To 120VAC
Rohs Compliant
No
Contact Rating
18A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Class 8502 Type WF
Vacuum Contactor
5/98
File E78351
CCN NLDX2
LR75167, 75168
Class 3211-04
Electrical Ratings
General Information
Class 8502 Type W non-reversing vacuum
contactors are a new addition to the Square D line
of contactors. These contactors are used to switch
capacitors, transformers and electric motors
where overload protection is separately provided.
Type W vacuum contactors are designed for
operation at 600 Volts, 50/60 Hertz.
By design, these contactors are well suited to
heavy-duty applications in harsh environments.
The power contacts are sealed in ceramic tubes,
called vacuum interrupters or vacuum bottles,
where the air has been evacuated. Arc quenchers
are not required because any arc formed between
opening contacts is not sustained due to the
presence of the vacuum. The arc is extinguished
when the current crosses zero after the contacts
are opened, therefore the arc typically does not
survive more than one half cycle. There is one
vacuum interrupter or bottle per pole, therefore a
three pole contactor has three vacuum
interrupters or bottles. The power contacts are not
affected by ambient conditions or contamination.
This provides for long life and reliable operation in
harsh applications.
Characteristic
Maximum Motor HP at:
200 V
230 V
380 V
460 V
575 V
3 Phase Capacitor Switching – KVAR
230 V
460 V
575 V
Transformer Switching – KVA 3 Phase, 3-Pole
240 V
480 V
600 V
Coil Data
Inrush VA
Sealed VA
Sealed Watts
Pick-up Volts
Drop-out Volts
Pick-up Time (ms)
Drop-out Time (ms)
Additional Electrical Characteristics
Number of Poles
Max. Voltage Rating
Enclosed Ampere Rating
Max. Closing Current
Max. Interrupting Current
Short Time Current (RMS):
Dielectric Strength, volts
Max. Allowable Interrupting
Impulse Voltage, VA (1 x 40ms)
1 second
2 seconds
© 1998 Square D All Rights Reserved
Size 4
40
50
75
100
100
40
80
100
23
47
59
300
30
6
70% of rated coil voltage
50% of rated coil voltage
18-22
90-120
3
600
135
1600
1600
2400
1600
5375
1200/hr
15000
Size 5
75
100
150
200
200
80
160
200
47
94
117
600
20
20
24-32
96-100
3
600
270
3000
3000
4500
3000
5375
1200/hr
15000
Size 6
150
200
300
400
400
160
320
400
94
188
234
1450
32
30
24-32
96-100
3
600
540
6000
6000
9000
6000
5375
1200/hr
15000
Altitude
The vacuum contactor is designed to tolerate
normal barometric pressure variances up to 6600
feet above sea level. If the contactor is to be used
above 6600 feet above sea level, please consult
the factory.
Termination Means
The Size 4 vacuum contactor is supplied with line
and load side lugs
contactors are supplied without line and load side
lugs. Class 9999 Type LUW5 and LUW6 lug kits
are available for the Size 5 and 6 contactors.
These kits include six lugs and the necessary
mounting hardware.
Auxiliary Contacts
An auxiliary contact block, Class 9999 Type
WX11, with one normally-open contact and
normally-closed contact is used with the Size 4, 5
and 6 vacuum contactors.
Auxiliary Contact Units
Auxiliary contact units may be added in the field.
the table below shows the maximum number of
units that may be added to a given size contactor
(in addition to the coil auxiliary contact).
Terminals
Class 8502
Size 4
Size 5
Size 6
Size
4
5c
6c
c
q
Power terminal lugs are not supplied on Size 5 and 6 contactors.
Values in table reflect those for the Size 5 and 6 lug kits, Class 9999
Type LUW5 and LUW6 respectively.
Solid or stranded copper wire.
Power Terminals
Wire Sizeq
Min. – Max.
#12-4/0
One #0-500 kcmil per phase
Two #0-500 kcmil per phase
t
. The Size 5 and 6 vacuum
3
4
4
Application Data
Control Terminals
Wire Sizeq
Min. – Max.
#16-12
#16-12
#16-12
23

Related parts for 8536SBO2V02H20S