8536SBO2V02H20S SQUARE D, 8536SBO2V02H20S Datasheet - Page 10

Magnetic Motor Starter

8536SBO2V02H20S

Manufacturer Part Number
8536SBO2V02H20S
Description
Magnetic Motor Starter
Manufacturer
SQUARE D
Datasheets

Specifications of 8536SBO2V02H20S

No. Of Phases
Three
Power Rating
5hp
Current Rating
18A
Peak Reflow Compatible (260 C)
No
Supply Voltage Max
460VAC
Control Voltage Max
120V
Leaded Process Compatible
No
Switch Function
3PST
Current, Rating
18 A
Enclosure Type
Open
Horse Power Rating
3 @ 230 VAC, 5 @ 480 VAC
Relay Type
Contactor
Standards
UL Listed File E78351 CCN NLDX - CSA Certified File LR60905 Class 3211 04
Voltage, Coil
24 VAC
Supply Voltage Range
110VAC To 120VAC
Rohs Compliant
No
Contact Rating
18A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz—Three Thermal Units Required
Coil Voltage Codes
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data.................................................................... Pages 13-16
Dimensions............................................................................ Pages 17-20
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701
NEMA
Size
00
0
1
2
3
4
5
6
7
k
j
c
t
Voltage
60 Hz
24q
120
208
240
480
600
Specify
q
For NEMA Type 3R enclosed devices (Sizes 0-4 only), change “A” in Type designation to “H”, no additional charge. Consult Factory for restrictions on available Forms in NEMA Type 3R
enclosures.
120 Volt Polyphase starters are wired for separate control.
Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes in table below and insert
as shown in the HOW TO ORDER block.
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
5/98
Continuous
Current
Ratings
9
18
27
45
90
135
270
540
810
50 Hz
. . .
110
. . .
220
440
550
Specify
Motor
Volts
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Max.
HP
1
1
2
2
3
3
5
5
7
7
10
10
10
15
25
25
25
30
50
50
40
50
100
100
75
100
200
200
150
200
400
400
300
600
600
1
1
1
1
2
2
2
2
Code
VO1
VO2
VO8
VO3
VO6
VO7
V99
t
Coil
Voltage
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Class E, F, & G
Bolted Type
Cast Ironc
USE Size 0
SBT2V02S
SBT2V08
SBT2V03
SBT2V06
SBT2V07
SCT3V02S
SCT3V08
SCT3V03
SCT3V06
SCT3V07
SDT1V02S
SDT1V08
SDT1V03
SDT1V06
SDT1V07
. . .
. . .
. . .
. . .
. . .
© 1998 Square D All Rights Reserved
How to Order:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
To Order Specify:
Cast
Aluminum
SBT42V02S
SBT42V08
SBT42V03
SBT42V06
SBT42V07
SCT43V02S
SCT43V08
SCT43V03
SCT43V06
SCT43V07
SDT41V02S
SDT41V08
SDT41V03
SDT41V06
SDT41V07
SET43V02S
SET43V08
SET43V03
SET43V06
SET43V07
SFT41V02S
SFT41V08
SFT41V03
SFT41V06
SFT41V07
SGT41V02S
SGT41V08
SGT41V03
SGT41V06
SGT41V07
. . .
. . .
SPIN TOP
Type
USE Size 0
SBR2V02S
SBR2V08
SBR2V03
SBR2V06
SBR2V07
SCR3V02S
SCR3V08
SCR3V03
SCR3V06
SCR3V07
SDR1V02S
SDR1V08
SDR1V03
SDR1V06
SDR1V07
SER3V02S
SER3V08
SER3V03
SER3V06
SER3V07
SFR1V02S
SFR1V08
SFR1V03
SFR1V06
SFR1V07
SGR1V02S
SGR1V08
SGR1V03
SGR1V06
SGR1V07
. . .
. . .
Class
8536
Catalog Number
®
SBA2
Type
NEMA Type 9
Hazardous Locations
Class II, Groups E, F, & G
Type
USE Size 0
SBE2V02S
SBE2V08
SBE2V03
SBE2V06
SBE2V07
SCE3V02S
SCE3V08
SCE3V03
SCE3V06
SCE3V07
SDE1V02S
SDE1V08
SDE1V03
SDE1V06
SDE1V07
SEE1V02S
SEE1V08
SEE1V03
SEE1V06
SEE1V07
SFE1V02S
SFE1V08
SFE1V03
SFE1V06
SFE1V07
SGE1V02S
SGE1V08
SGE1V03
SGE1V06
SGE1V07
. . .
. . .
Voltage
Code
VO2
Coil
Form(s)
H3O
Selection – Class 8536
NEMA Type 12/3Rk
Dusttight & Driptight
Industrial Use
Enclosure
Type
Use Size 0
SBA2V02S
SBA2V08
SBA2V03
SBA2V06
SBA2V07
SCA3V02S
SCA3V08
SCA3V03
SCA3V06
SCA3V07
SDA1V02S
SDA1V08
SDA1V03
SDA1V06
SDA1V07
SEA1V02S
SEA1V08
SEA1V03
SEA1V06
SEA1V07
SFA1V02S
SFA1V08
SFA1V03
SFA1V06
SFA1V07
SGA1V02S
SGA1V08
SGA1V03
SGA1V06
SGA1V07
SHA2V02S
SHA2V08
SHA2V03
SHA2V06
SHA2V07
SJA2V02S
SJA2V08
SJA2V03
SJA2V06
SJA2V07
9

Related parts for 8536SBO2V02H20S