SI-QS90ME BANNER ENGINEERING, SI-QS90ME Datasheet - Page 6

SWITCH, SAFETY INTERLOCK, 2NC, 10A

SI-QS90ME

Manufacturer Part Number
SI-QS90ME
Description
SWITCH, SAFETY INTERLOCK, 2NC, 10A
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of SI-QS90ME

Contact Configuration
DPST-NC
Contact Voltage Ac Max
230V
Contact Voltage Dc Max
24V
Contact Current Ac Max
10A
Contact Current Dc Max
6A
Switch Terminals
Screw
Contact Current Max
10A
Circuitry
DPST-NC
Machine Safety Switches –
Safety switches should be checked at each shift change or machine setup by a
designated person (see below) for:
1. Breakage of the switch body or actuator,
2. Good alignment and full engagement of the actuator with the receptor,
3. Confirmation that the safety switch is not being used as an end stop,
4. Loosening of the switch or actuator mounting hardware, and
5. Verification that it is not possible to reach any hazard point through an opened guard
In addition, a qualified person should check for the following on a periodic schedule
determined by the user based upon the severity of the operating environment and the
frequency of switch actuations:
1. Check the wiring chamber for signs of contamination.
2. Check the contacts for signs of deterioration or damage.
3. Inspect the electrical wiring for continuity and damage.
4. Verify that wiring conforms to the instructions on pages 3 and 4 of this data sheet.
A designated person is identified in writing by the employer as being appropriately trained
to perform a specified checkout procedure. A qualified person possesses a recognized
degree or certificate or has extensive knowledge, training, and experience to be able to
solve problems relating to the safety switch installation (ANSI B30.2).
Do not attempt any repairs to the switch. It contains no field-replaceable
components. Return the switch to the factory for warranty repair or replacement.
If it ever becomes necessary to return a switch to the factory, please do the following:
1. Contact the Banner applications engineering department at the number or address
2. Pack the switch carefully. Damage which occurs in shipping is not covered by

(or any opening) before hazardous machine motion has completely stopped.
listed on the front cover. They will attempt to troubleshoot the system from your
description of the problem. If they conclude that a component is defective, they will
issue an RMA (Return Merchandise Authorization) number for your paperwork, and
give you the proper shipping address.
warranty.
P/N 49370 rev. E
Periodic Checks
Repairs
SI-QS75 and SI-QS90 Series Flat Pack Style
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164