OT40F3 ABB, OT40F3 Datasheet

no-image

OT40F3

Manufacturer Part Number
OT40F3
Description
SWITCH,DISCONNECTOR,3P,40A
Manufacturer
ABB
Series
OTr
Datasheet

Specifications of OT40F3

No. Of Poles
3
Svhc
No SVHC (18-Jun-2010)
Current Rating
40A
External Depth
45mm
External Length / Height
56mm
External Width
35mm
Terminal Type
Clamp
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Low Voltage Switches
Switches
Switch-disconnectors

Related parts for OT40F3

OT40F3 Summary of contents

Page 1

... Low Voltage Switches Switches Switch-disconnectors ...

Page 2

IEC OT16F OT63F OT100F OT25F OT80F OT125F OT40F lth / 115 125 le /AC22A, ≤ 415V 100 125 le /AC23A, ≤ 415V OT200E ...

Page 3

... Technical data ................................................................................................................6-14 Ordering information ...................................................................................................15-41 Switch-disconnectors, base and DIN-rail mounting ................................................ 15 Switch-disconnectors, base mounting ............................................................... 16-19 Switch-disconnectors, door mounting ..................................................................... 19 Switch-disconnectors, side operated, earthing switches ........................................ 20 UL/CSA Non-fusible disconnect switches ............................................................... 21 Accessories, selection overview ......................................................................... 22-23 Optional handles ................................................................................................. 24-28 Legend plates and handle accessories .................................................................... 29 Extended shafts and shaft accessories .............................................................. 30-31 Auxiliary contacts and mounting accessories ...

Page 4

... From 16 to 3150 A, 690 V The switch-disconnectors are suitable for diverse applications, in motor control centers, in switchboards and as main switches in various equipment and machines. From single to 8-poles front operated switches with pistol handle or direct mounted handle. For installation in enclosures, side operated switches, switches with wide phase distance and combination switches for change-over, bypass, reversing etc ...

Page 5

... The adjustable mounting feet allow both top and side mounting of the switch. ABB’s switch-disconnector range meets disconnect and isolation requirements more effectively than ever, maximizing the benefits and optimizing your use of assets. 5 ...

Page 6

Switch-disconnectors OT 16...160 Technical data Technical data according to IEC 60947-3 Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 Dielectric strength Rated impulse withstand voltage Rated thermal current and rated operational current AC20/DC20 ambient 40°C ambient 40°C ...

Page 7

Switch-disconnectors OT 16...160 Technical data OT40_ OT63_ OT80_ 750 750 750 ...

Page 8

Switch-disconnectors OT 200..800 Technical data Technical data according to IEC 60947-3 Rated insulation voltage and rated operational voltage AC-20, DC-20 Dielectric strength Rated impulse withstand voltage Rated thermal current and rated operational current AC-20, DC-20 in ambient 40 °C 4) ...

Page 9

Switch-disconnectors OT 200..800 Technical data 200 250 OT200E_ OT250_ 1 000 1 000 200 250 200 250 95 120 200 250 200 250 200 250 200 250 200 250 200 250 200 250 200 250 135 ...

Page 10

Switch-disconnectors OT 1000...2500 and OETL 1250...3150 Technical data Technical data Technical data according to IEC 60947-3 Rated insulation voltage and rated operational voltage AC20/DC20 Dielectric strength Rated impulse withstand voltage Rated thermal current and rated operational current AC20/DC20 ..with minimum ...

Page 11

Switch-disconnectors OT 1000...2500 and OETL 1250...3150 Technical data Technical data 1000 1250 OT1000 OT1250 1 000 1 000 000 1 250 1 000 1 250 2x300 2x400 1 000 1 250 1 000 1 250 ...

Page 12

... Max. OFA_fuse size gG/aM Rated short-time withstand current r.m.s. -value I Rated short circuit making capacity Peak value I Power loss / pole Mechanical endurance Weight without accessories UL Listed switches are also CSA Approved 1) Fuse size 70A for RK5 2) 200A/min use busbar connections OEZXX16/13 or OZXT2 3) 2 ...

Page 13

... Non fusible disconnect switches OT 16...600 Technical data OT40_ OT63_ OT80_ UL508 & IEC UL508 & IEC UL508 & IEC UL 98 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL 98 & IEC 600 600 600 10/28.0 15/42.0 20/54.0 20/27 ...

Page 14

... Max. OFA_ fuse size gG/aM 690 V Rated short-time withstand current R.M.S. -value I Rated short circuit making capacity Peak value I Power loss / pole Weight without accessories Terminal bolt size UL Listed switches are also CSA Approved 1) Max. distance between busbar support and switch terminal 70 mm IEC60947-3 category ...

Page 15

... Handle and shaft included 2) Cable cross Rated operat. Type th (open) section currents [mm ] AC22A/AC23A 2 400V [A/A] 25 0.75... OT16F3 25 0.75... OT16F4N2 32 0.75... OT25F3 32 0.75... OT25F4N2 40 0.75... OT40F3 40 0.75... OT40F4N2 63 1.5... OT63F3 63 1.5... OT63F4N2 80 1.5... OT80F3 80 1.5... OT80F4N2 115 10...70 100 / 80 OT100F3 115 10...70 100 / 80 OT100F4N2 125 10 ...

Page 16

... OT315 - 400E03P 3 Shafts and handles included as standard Suitable for switches OT315 - 400E04P OT200…250_P OT315…400_P OT630…800_P OT630 - 800E03P OT630 - 800E04P Include a detachable neutral link integrated into the mechanism 1SCC301001C0201 Rated operat. Type th (open) currents [A] AC22A/AC23A 400V [A/A] 200 200/200 ...

Page 17

... Including an IP54 metallic handle with I-O-indication. Padlockable in the O-position OT2000 - 2500E03P Shafts and handles included as standard Suitable for switches OT1000...1250_P OT1600_P OT2000…2500_P OETL3150 OETL3150K3 Extra thick (20 m) silver coating on the contacts. 1) With extended phase distances OETL 2500K185/3150K185:185 mm Handle and shaft have to be ordered separately 3) Rated oper ...

Page 18

... ON-position. The shaft is adjustable for a range of installation depths OT1000-1600E03K OT2000-2500E03K 3 4 Shafts and handles included as standard Suitable for switches OT200…250_K OT315…400_K OT630…800_K OT1000...1250_K OT1600_K OT2000...2500_K OT200 - 250E03W OT200…250_P OT315…400_P OT315 - 400E03W 18 19 1SCC301001C0201 Rated operat. Type th (open) currents [A] ...

Page 19

... 40FT3 4 115 3 125 4 125 3 200 4 200 Shafts and handles included as standard 80FT3 Suitable for switches OT1000...1250_P OT1600_P OT2000...2500_P OT160ET OT 100 - 125FT3 W4 = Phase distance 140 mm OT 160ET3 W8 = Phase distance 185 mm Rated operat. Type th (open) currents [A] AC22A/AC23A 400V [A/A] ...

Page 20

... Including terminal bolt kit, a black Test-ON-OFF plastic handle and shaft as standard. The handle is padlockable in the OFF-position OETL1250M3 Earthing switches, base mounting Including a black IP65 handle with Number of poles Shafts and handles included as standard Suitable for switches OT200...250 OT315...400 OT630..800 OETL1250 ...

Page 21

... OT30...1200: UL 98, CSA 22 OETL - NF 1600 - 2000P - OETL-NF: UL98, CSA 22- IEC 60947-3 Type rating 3-phase [HP] [A] 240V 480V 600V OT16F3 OT16F4N2 OT16FT3 OT16FT4N2 30 7 OT25F3 30 7 OT25F4N2 30 7 OT25FT3 30 7 OT25FT4N2 OT40F3 OT40F4N2 OT40FT3 OT40FT4N2 OT63F3 OT63F4N2 OT63FT3 OT63FT4N2 OT80F3 OT80F4N2 ...

Page 22

Accessories Technical data 22 1SCC301001C0201 ...

Page 23

Accessories Technical data 23 1SCC301001C0201 ...

Page 24

... Optional handles Ordering information Optional handles, base and DIN-rail mounted switches Handle knobs Mounting directly to the switch, no shaft needed. OHBS 1_ Padlockable with one padlock with bail diameter 5 mm, see the table below Colour OHBS 12 Black Black Red Red Black Red OHRS 2_ ...

Page 25

... Optional handles Ordering information Optional handles, base and DIN-rail mounted switches for shaft diameter 6 mm, door drilling 22.5 mm. The type and the ordering numbers are for one piece. Selector type handles Indication I-O and ON-OFF Colour OH_ handles, NEMA 1 Black Yellow-red OT16...80F ...

Page 26

... Optional handles Ordering information Optional handles, base and DIN-rail mounted switches Pistol type handles OH_ handles: IP 65, NEMA 1,3R, 12, padlockable with three padlocks in OFF-position, door interlock in ON-position. Screw fixing from the back side of the handle. No screws on the front ensures double insulation. The type and the ordering numbers are for one piece. ...

Page 27

... Optional handles Ordering information Optional handles, base mounted switches Handles for direct mounting Colour Indication Test-OFF-ON/Test-O-I. Padlockable with three padlocks in OFF-position. Includes shaft and mechanism cover. Black OTV_ Yellow-red 65 Black Yellow-red 95 Black Yellow-red 125 Black Metallic handles IP65, NEMA 1, 3R, 4, 4x, 12, padlockable with 3 padlocks in OFF- position, door interlock in ON-position. ...

Page 28

... Grey Padlockable with max. 3 padlocks, IP 65, hole distance 36/48 mm, NEMA 1, 3R, 12 Black Yellow-red Silver Grey Pistol handle mounting kit for OT 100...125 FT_ switches Pistol handle is not included Screw mounting Black OHZX6 • Door interlocking in ON-position means that the door can not be opened, when the handle is in ON-position ...

Page 29

Legend plates and handle accessories Ordering information Legend plates for selector type handles Description Plain plates for OH 1_ and OH 3_handles. Black OPY_ Yellow Silver Grey Plain plates for OH 2_ handles. Black Yellow Silver Grey OPB 3 Printed ...

Page 30

... Longer shafts on request 30 31 1SCC301001C0201 H Suitable for Type switches [mm] See OT16...125F OXS6X85 dimension OT16...125F OXS6X105 drawings OT16...125F OXS6X120 OT16...125F OXS6X130 OT16...125F OXS6X160 OT16...125F OXS6X180 OT16...125F OXS6X250 OT16 ...

Page 31

... Shaft extension socket For extending the shaft of combination attachment. Shaft diameter [mm Adapter for extension socket The adapter can be placed inside the extension socket OETLZX95. 6 Suitable for Type switches OT16...125F OXP6X150-45 OXP6X170-45 OT16...125F OXP6X265-45 OT16...125F OXP6X400-45 OT200...250_ OXP6X130-45 OT200...250_ OXP6X150-45 OT200 ...

Page 32

... Early break type auxiliary contacts means that in the switches, the NO aux.contacts break before the main contacts open. Performance data of auxiliary contacts, see next page. The contact timing: see the charts on page 64. unit 4) [kg] 0.03 0.03 0.03 ...

Page 33

... Early break type auxiliary contacts means that in the switches, the NO aux.contacts break before the main contacts open. 1SCC301001C0201 unit [kg] 0.12 0.12 0.18 0.09 0.12 0.18 Weight/ unit [kg] 0.03 0.02 0.01 0.01 ...

Page 34

... OT 100...125F OT 160E3, ET3 OT 16...40FT3 OT 63...80FT3 OT 100...125FT3 OXN_ Neutral links Suitable for switches Detachable, mountable separately to the base plate OT200...250 OT 315...400 OT 630...800 OT1000…1250 Mountable separately to the base plate OESAZX_ N1=On the left side of the switch ...

Page 35

... OT 100...125F3, FT3 OT160E3 OT100...125F3 with terminal clamps OZXL1 or OZXT1 OTS 160T1 OTS_T1 For 4-pole switches OT160E4 For 1 to 4-pole switches, shroud for single pole and for fourth pole OTP_40F_ OTP_80F_ OTP_125F_ OT160E_ For OT100...125E3 with terminal clamps OTS_L_ OTS_S_ ...

Page 36

... OT600U, OT630...800E, 3- and 4-pole OT1000…2500, 3- and 4-pole Phase barriers The phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OT200...800 switch discon- nectors. 3-pole switch disconnectors need 4 barriers and 4-pole switch disconnectors need 6 barriers for full protection. ...

Page 37

... Connecting accessories Ordering information Terminal clamp sets for Al- and Cu-cables OZXB type Al/Cu connectors made of stainless steel Suitable for switches OT1000...1600 95…185 OZXR2X300 OZXP2X240 OT2000…2500 OZXP240 OETL3150 OZXR240 OZXR type Al/Cu connectors made of stainless steel and copper OT200…250 OT200… ...

Page 38

... OT200 - 250 OT315 - 400 OESAZW1 OT630-800 A By-pass switch mechanism A combination of two switches in parallel with a third switch for change-over operation to by-pass , for example, a breaker for maintenance. The by-pass attachment can be used together with another combination attachment. Three 3 or 4-pole switches needed 125 OTZW25, ...

Page 39

... Change-over switches OESAZW1 OTZW25 OETLZW11 OETLZW12 By-pass switches OTZW17 OTZW26 OETLZW13 Mechanical interlock OTZW24 OTZW10 OETLZW14 OETLZW3 OETLZW15 Change-over switches, 6- and 8 pole switches By-pass switches Included in conversion kit delivery Shaft Handle Shaft x OHBS1A_ - (shaft dia 6 mm) x OHBS1A_ - (shaft dia 6 mm) x OHBS1A_ ...

Page 40

... Cam attachment for Castell, Lowe & Fletcher or Ronis interlock. Lock, handle or shaft not included. Mounting to OXP-shaft, works together with OH-door handle and a shaft. This accessory is mounted to the operating shaft of the switch and therefore only compatible with external handles. Suitable for switches OETLZW 16, 5 OT16...250 OT315 ...

Page 41

... OFF position or both in the OFF and ON positions. The electrical interlock works using the “closed circuit principle”, meaning that when the control voltage is not connected to the coil, the switches provided with A-type interlocks cannot be turned to the ON position and switches with L-type interlocks cannot be turned to the ON or OFF positions ...

Page 42

Front operated switch-disconnectors, base mounting Dimension drawings OT 16...40F3, _F4 OT 63...80F3, _F4 42 43 1SCC301001C0201 ...

Page 43

Front operated switch-disconnectors, base mounting Dimension drawings OT 30, 60, 100, 125F3, _F4 OT 160E3 1SCC301001C0201 ...

Page 44

Front operated switch-disconnectors, base mounting Dimension drawings OT 16...40F6, _F8 OT 63...80F6, _F8 44 45 1SCC301001C0201 ...

Page 45

Front operated switch-disconnectors, base/door mounting Dimension drawings OT 100...125F6, _F8 OT 16...40FT3, _FT4 OT 63...80FT3, _FT4 45 1SCC301001C0201 ...

Page 46

Front operated switch-disconnector, door mounting Dimension drawings OT 100...125FT3, _FT4 OT 160ET_ 46 47 1SCC301001C0201 ...

Page 47

Front operated switch-disconnectors, base mounting Dimension drawings OT 200_P and OT 250_P OT 315_P and OT 400_P 47 1SCC301001C0201 ...

Page 48

Front operated switch-disconnectors, base mounting Dimension drawings OT 315_P and 400_P OT 630_P and OT 800_P 49 48 1SCC301001C0201 ...

Page 49

Front operated switch-disconnectors, base mounting Dimension drawings OT 1000_P, OT 1250_P, OT 1600_P and OT 800U_P, OT 1200U_P 49 1SCC301001C0201 ...

Page 50

Front operated switch-disconnectors, base mounting Dimension drawings OT 2000_P and OT 2500_P 51 50 1SCC301001C0201 ...

Page 51

Front operated switch-disconnectors, base mounting Dimension drawings OETL 3150 K_ OETL 3150 KV_ 51 1SCC301001C0201 ...

Page 52

Front operated switch-disconnectors, base mounting Dimension drawings OT 200_WP and OT 250_WP OT 315_WP and OT 400_WP OT 1000_W_P...OT 2000_W_P 1SCC301001C0201 see pages 49 and 50 ...

Page 53

Front operated switch-disconnectors, base mounting Dimension drawings OT 200_K and OT 250_K OT 315_K and OT 400_K OT 630_K and OT 800_K Other switch dimensions, please see pages 49 and 50 53 1SCC301001C0201 ...

Page 54

Front operated switch-disconnectors, base mounting Dimension drawings Dimension drawings OT 200U_P OT 400U_P OT 600U_P OT 800U_P...OT 1200U_P, see page 1SCC301001C0201 ...

Page 55

Front and side operated switch-disconnectors, base mounting Dimension drawings Dimension drawings OETL-NF1600P and OETL-NF2000P OT 200ES_ and OT 250ES_ OT 315ES_ and OT 400ES_ 55 1SCC301001C0201 ...

Page 56

... Side operated switch-disconnectors and earthing switches Dimension drawings OT 630ES_ and OT 800ES_ OETL 1250M_ OETL 1250 1SCC301001C0201 OETL 1250 M140_ ...

Page 57

... Handles Dimension drawings Handles for base and DIN-rail mounted switches OH_S1A_ OH_S3A_ A OH_S1A_ 31,5 OH_S3A_ 37,5 Handles for door mounted switches (snap-on mounting) OH_S1P_ OH_S3P_ A OH_S1P_ 31,5 OH_S3P_ 37,5 Handles for door mounted switches (screw-mounting) OH_S1R_ OH_S3R_ A OH_S1R_ 31,5 OH_S3R_ 37,5 ...

Page 58

Handles Dimension drawings Round padlockable handle OZ331P_ and OZ371P_ OZ331P_ 3-10 Plastic handles OH_ 58 59 1SCC301001C0201 OZ371_ 21 4-5 Door drilling for OH_ -handles: Handle type Handle length (mm) Shaft (mm OH_45J6 45 6 ...

Page 59

Handles, legend plate Dimension drawings Minimum distance L, between the hinge and the rotating shaft Switch size OT16...125 OT160...250_P OT315...400_P OT630...800_P OETL3150 hinge shaft Legend plate for pistol handles, OPB3, OPY3 and OPX3 Metallic handles YASDA ...

Page 60

Connection busbars, motor operator Dimension drawings Connection busbars for OETL 3150 OETLZX 114, 114/1 Alternative 1 - vertical/back mounting Motor operator OEMO Electrical and mechanical interlock OTZT_ 61 60 1SCC301001C0201 OETLZX 114, 114/1 Alternative 2 - edgewise mounting OETLZX 115, ...

Page 61

Conversion kits Dimension drawings 6 and 8-pole mechanism OESAZW 2 Mechanical interlock mechanism OETLZW 3, 14, 15 OTZW 8 min OT16...40F 45mm +(0...12)x15 OT63...80F 60mm +(0...11)x15 OT100...125F 75mm +(0...10)x15 OETLZW 9 OTZW 10 1SCC301001C0201 ...

Page 62

Conversion kits Dimension drawings Change-over and by-pass mechanism OESAZW1 62 63 1SCC301001C0201 OTZW 17 ...

Page 63

Switch-disconnectors Dimension drawings Handle indications, contact functions Handle indications and functions • The handle indicates the position of the contacts with complete reliability in all situations. If the contacts are welded together, the handle doesn´t reach the OFF-position but remains ...

Page 64

Switch-disconnectors Contact functions Dimension drawings ON and OFF-functions of main and auxiliary contacts OT 16...160 Auxiliary contact Contact configuration OA1G10, 1NO OA1G01 1NC OBEA 10+, OEZNP 1 1NO OBEA 01+, OEZNP 1 1NC OT 63...125 OA1G10 OA1G01 ON and OFF-functions ...

Page 65

... OETL1250M140 1SCA022126R6950 20 Earthing switches, base mounting OETL1250M3 1SCA022102R1410 20 Earthing switches, base mounting OETL1250M4 1SCA022189R0930 20 Earthing switches, base mounting OETL1250M4-140 1SCA022290R5680 20 Earthing switches, base mounting OETL3150K185 1SCA022136R7550 17 Front operated switch-disconnector OETL3150K3 1SCA022115R6340 17 Front operated switch-disconnector OETL3150K3-2 1SCA022157R4260 17 Front operated switch-disconnector OETL3150K3-H20 1SCA022163R8090 ...

Page 66

Index Type Order number Page Description OHY65J6T 1SCA022456R9540 26 Pistol type handle OHY65J6TE00S 1SCA022688R0140 27 Handle for side operated switch disconnector OHY80J6 1SCA022381R0410 26 Pistol type handle OHY95J12 1SCA022381R1050 26 Pistol type handle OHY95J12T 1SCA022736R1910 26 Pistol type handle OHYS1AH ...

Page 67

... OT400U12P 1SCA022754R6960 21 Front operated, non-fusible disconnect switch OT400U22P 1SCA022762R7290 21 Front operated, non-fusible disconnect switch OT40F3 1SCA104902R1001 15 Front operated switch-disconnector OT40F3 1SCA104902R1001 21 Front operated, non-fusible disconnect switch OT40F4N2 1SCA104932R1001 15 Front operated switch-disconnector OT40F4N2 1SCA104932R1001 21 Front operated, non-fusible disconnect switch OT40F6 1SCA104936R1001 ...

Page 68

Index Type Order number Page Description OT800E03P 1SCA022718R9410 16 Front operated switch-disconnector OT800E04K 1SCA022779R5240 18 Front operated switch-disconnector with direct mounted handle OT800E04P 1SCA022719R2110 16 Front operated switch-disconnector OT800E12P 1SCA022753R5170 16 Front operated switch-disconnector OT800E22P 1SCA022753R5250 16 Front operated switch-disconnector ...

Page 69

Index Type Order number Page Description OXT20x210X 1SCA103684R1001 31 Shaft tube for OT1000...2500 OZ331P67B 1SCA111427R1001 25 Round padlockable handles OZ331P67RY 1SCA111429R1001 25 Round padlockable handles OZ331SPB 1SCA113097R1001 25 Round padlockable handles OZ331SPRY 1SCA112983R1001 25 Round padlockable handles OZ371PB 1SCA111684R1001 25 ...

Page 70

Notes 70 71 1SCC301001C0201 ...

Page 71

Notes 71 1SCC301001C0201 ...

Page 72

... Contact us ABB Oy Low Voltage Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations. ...

Related keywords