PSR-FAN3-45 ABB, PSR-FAN3-45 Datasheet

no-image

PSR-FAN3-45

Manufacturer Part Number
PSR-FAN3-45
Description
FAN, ABB SOFTSTARTER
Manufacturer
ABB
Datasheet

Specifications of PSR-FAN3-45

Svhc
No SVHC (18-Jun-2010)
Accessory Type
Fan
For Use With
PSR3 - PSR37 Soft Starters
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Normal start:
In Line connected
Number of starts per hour using PSR softstarters
Data based on an ambient temperature of 40°, starting current of 4 x I
If using manual motor starters
type 1 coordination will be
achieved.
Using gG fuses type 1
coordination will be achieved.
Suitable switch fuse for the
above gG fuses.
The overload relay is always
required to protect the motor.
6
1SFC132004C0201, Ed. 5
The line contactor is not required
for the softstarter itself but often
used to open if OL trips.
Motor-
current
I
105 A
e
12 A
16 A
25 A
30 A
37 A
45 A
60 A
72 A
85 A
3 A
6 A
9 A
Starts/hour without auxiliary fan
PSR16
PSR25
PSR30
PSR37
PSR72
PSR85
PSR105
(440-480 V) hp
10
PSR45
PSR60
IEC, Max. A
UL, Max. A
(400 V) kW
PSR85
PSR30
20
PSR9
PSR12
-
PSR105
PSR37
PSR45
PSR6
PSR60
PSR72 PSR85
30
PSR25
PSR105
-
Softstarter
PSR3
1.5
3.9
2
3.4
400V, 40 °C
Manual motor starter,
MS116
Fuse protection 400 V, 50 kA,
10 A
Switch fuse
OS32GD
Line contactor
A9
Thermal overload relay
TA25DU
By-pass contacs
Built-in
PSR3 ... PSR16
PSR16
PSR3
Softstarters
Type PSR
Overview
40
PSR37
PSR45
PSR60
-
-
PSR30
PSR72 PSR85 PSR105
PSR6
3
6.8
3
6.1
MS116
16 A
OS32GD
A9
TA25DU
Built-in
50
PSR12
PSR105
-
-
-
, Type
PSR25
, Type
PSR72 PSR85 PSR105
, Type
60
PSR45
PSR60
-
-
-
PSR9
4
9
5
9
MS116
25 A
OS32GD
A9
TA25DU
Built-in
PSR9
PSR16 PSR25
PSR37
80
-
-
-
-
Type
, Type
PSR30
e
and ramp time 6 seconds.
PSR6
PSR60
PSR72
OS32GD
PSR12
5.5
12
7.5
11
MS116
32 A
A12
TA25DU
Built-in
100
-
-
-
-
-
gG Fuse
Starts/hour with auxiliary fan
PSR16
7.5
16
10
15.2
MS116
32 A
OS32GD
A16
TA25DU
Built-in
10
PSR105
PSR16
PSR25
PSR30
PSR37
PSR72
PSR85
20
PSR45
PSR60
PSR25
11
25
15
24.2
MS132
50 A
OS32GD OS32GD
A26
TA25DU TA25DU
Built-in
PSR25 ... PSR30
PSR12
PSR30
PSR9
30
-
PSR105
PSR37
PSR30
15
30
20
28
MS132
63 A
A30
Built-in
PSR85
PSR6
40
-
PSR25
PSR45
PSR72
PSR3
PSR60
50
-
-
PSR105
PSR37
PSR16
PSR85 PSR105
PSR37 ... PSR45
PSR37
18.5
37
25
34
MS450
100 A
OS63GD
A40
TA42DU
Built-in
60
-
-
PSR45
PSR12
80
-
-
-
PSR60
PSR72
PSR25
PSR30
PSR45
22
45
30
46.2
MS450
125 A
OS125GD
A50
TA75DU
Built-in
PSR45
PSR9
100
-
-
-
-

Related parts for PSR-FAN3-45

PSR-FAN3-45 Summary of contents

Page 1

... A9 for the softstarter itself but often used to open if OL trips. Thermal overload relay The overload relay is always TA25DU TA25DU required to protect the motor. By-pass contacs Built-in Built-in Number of starts per hour using PSR softstarters Motor- Starts/hour without auxiliary fan current PSR3 ...

Page 2

... Built-in Built-in Built-in Description PSR - Compact range, covers motor currents from 3 to 105 the latest addition to the softstarter family and has an attractive, compact design. Further, the system concept includes MMS and the softstarters are available for remote control connection using the FieldBusPlug as an accessory ...

Page 3

... PSR72-600- PSR85-600- 105 PSR105-600-81 Type PSR-FBPA PSR16-MS116 PSR30-MS132 PSR105-MS495 . PSR-FAN3-45A PSR-FAN60-105A 1x10...50, 2x10...25 PSLW-72 2 Weight kg Order code 1 piece 1SFA 896 103 R7000 0.45 1SFA 896 104 R7000 0.45 1SFA 896 105 R7000 0.45 1SFA 896 106 R7000 0.45 1SFA 896 107 R7000 ...

Related keywords