XF2M-1415-1A-R100 Omron, XF2M-1415-1A-R100 Datasheet - Page 23

CONNECTOR FPC 14POS 0.5MM SMD

XF2M-1415-1A-R100

Manufacturer Part Number
XF2M-1415-1A-R100
Description
CONNECTOR FPC 14POS 0.5MM SMD
Manufacturer
Omron
Series
XF2Mr
Type
FPC Connectorr
Datasheets

Specifications of XF2M-1415-1A-R100

Connector Type
Top and Bottom Contacts
Number Of Positions
14
Pitch
0.020" (0.50mm)
Ffc, Fcb Thickness
0.30mm
Height Above Board
0.083" (2.10mm)
Mounting Type
Surface Mount, Right Angle
Cable End Type
Straight
Termination
Solder
Locking Feature
Rotary Lock, Backlock
Contact Finish
Gold
Contact Finish Thickness
5.9µin (0.15µm)
Operating Temperature
-30°C ~ 85°C
Current Rating
0.500A
Voltage Rating
50V
Housing Material
Liquid Crystal Polymer (LCP)
Contact Gender
SKT
Mounting Style
Surface Mount
Number Of Contact Rows
1
Number Of Contacts
14POS
Pitch (mm)
0.5mm
Body Orientation
Right Angle
Contact Resistance Max
50mOhm
Voltage Rating Max
50VDC/50VAC
Operating Temp Range
-30C to 85C
Current Rating (max)
0.5A
Housing Color
Natural
Contact Material
Copper Alloy
Contact Plating
Gold Over Nickel
Termination Method
Solder
Product Height (mm)
2mm
Product Depth (mm)
5.9mm
Product Length (mm)
11.1mm
Mounting Angle
Straight
Termination Style
Solder Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XF2M14151AR100
XF
Operating the XF Rotary Backlock
FPC Connector Part Names
Handling Methods
Inserting the FPC
1. Insert the FPC all the way to the back of the connector.
2. Activate the slider (lever) and lock the FPC in place.
Removing the FPC
1. Move the slider (lever) upwards to disengage the locking
2. Once the lock has been disengaged, pull the FPC out.
The slider (lever) shown locked
The slider (lever) shown open
Slider (lever)
mechanism.
Circuit board
Housing
Terminal
Hold-down
FPC
Precautions during Use
Operating
1. Do not lock the slider (lever) without an FPC inserted.
2. Do not lock or unlock the slider (lever) with excessive
3. When locking the slider (lever), apply pressure with your
Locking the slider (lever) without an FPC inserted will
increase the force required to insert an FPC.
force.
Doing so may result in damage to the connector or con-
tact failure.
Do not use a slider (lever) if it becomes detached.
fingertips to both sides of the slider (lever) and then twist
the slider (lever) until it comes away from the unit. Failing
to lock the slider (lever) properly may result in contact fail-
ure.
Do not apply force horizontally to the PCB when locking
the slider (lever). Doing so may result in damage to the
connector or contact failure.
XF
23

Related parts for XF2M-1415-1A-R100