PM4HA-H-24VS PANASONIC EW, PM4HA-H-24VS Datasheet
PM4HA-H-24VS
Specifications of PM4HA-H-24VS
Related parts for PM4HA-H-24VS
PM4HA-H-24VS Summary of contents
Page 1
... All types of PM4H timer have multi-time range. 16 time ranges are selectable 50h 1s to 500h (Max. range) is controlled. Part No. PM4HA-H-AC240VW PM4HA-H-AC240VSW PM4HA-H-24VW PM4HA-H-24VSW PM4HA-H-DC12VW PM4HA-H-DC12VSW PM4HA-H-AC240V PM4HA-H-AC240VS PM4HA-H-24V PM4HA-H-24VS PM4HA-H-DC12V PM4HA-H-DC12VS PM4HS-H-AC240VW PM4HS-H-AC240VSW PM4HS-H-24VW PM4HS-H-24VSW PM4HS-H-DC12VW PM4HS-H-DC12VSW PM4HS-H-AC240V PM4HS-H-AC240VS PM4HS-H-24V PM4HS-H-24VS PM4HS-H-DC12V PM4HS-H-DC12VS ...
Page 2
PM4H-A/S/M CHARACTERISTICS Item Rated operating voltage Rated frequency Rated power consumption Output rating Rating Operating mode Time range Operating time fluctuation Time Setting error accuracy Voltage error Note:) Temperature error Contact arrangement Contact Contact resistance (Initial value) Contact material Mechanical ...
Page 3
PARTS NAME PM4H-S Power indicator LED Time indicator window Time range indicator Time range selector 16 time settings selectable 500 10s 50s 1min 5min 10min 50min 1h 5h 10h 50h 10h 50h 100h 500h ...
Page 4
PM4H-A/S/M OPERATION MODE PM4H-A Operation mode Turn the operation selector to Power is applied continuously. When a start signal is applied, the time cycle begins. The output contacts change state after the time delay is completed. The contacts will return ...
Page 5
Operation mode Turn the operation selector to Power is applied continuously. When a start signal is applied, the out- put contacts change state immediately and time cycle begins. When the time delay is completed, the output contacts return to their ...
Page 6
PM4H-SD/SDM DIN48 SIZE ANALOG STAR ( )-DELTA ( ) TIMERS UL File No.: E122222 CSA File No.: LR39291 48 1.890 mm inch 66.5 48 2.618 1.890 CHARACTERISTICS Item Rated operating voltage Rated frequency Rated power consumption Rating Output rating Operation ...
Page 7
PRODUCT TYPE Operation Type Contact arrangement mode PM4H-SD Relay Timed-out Star ( )-Delta side: 1 Form switching side: 1 Form A PM4H-SDM Relay Timed-out Star ( )-Delta side: 1 Form switching side: 1 Form ...
Page 8
PM4H-F UL File No.: E122222 CSA File No.: LR39291 48 1.890 mm inch 62.5 48 2.461 1.890 CHARACTERISTICS Item Rated operating voltage Rated frequency Rated power consumption Rating Output rating Operation mode Time range Operation time fluctuation Setting error Time ...
Page 9
PRODUCT TYPE Operation Type Contact arrangement mode Power Relay Timed-out PM4H-F8 OFF-delay 2 Form C (without reset) Power OFF-delay Relay Timed-out PM4H-F8R (with 1 Form C instantaneous reset) When ordering CE type, please order the Part No. with suffix CE. ...
Page 10
PM4H-F Operation Type Contact arrangement mode Power OFF-delay Relay Timed-out PM4H-F11R (with 2 Form C instantaneous reset) When ordering CE type, please order the Part No. with suffix CE. (e.g. PM4HF11R-S-AC120VWCE) DIMENSIONS • Screw terminal type (embedded mounting) 12.0 6.0 ...
Page 11
WIRING DIAGRAMS • PM4H-F8 (no reset input) Pin type Time-delay 2C N.C. N.C. N.O. N.O. COM COM (–) Operating (+) voltage PM4H-F (WITH RESET) INPUT CONDITIONS 1. Contact operating input (pin type example) PM4H-F8R PM4H-F11R Reset input Use a contact ...
Page 12
Notes for PM4H series MODES & TIME SETTING 1) Operation mode setting [PM4H-A] 8 operation modes are selectable with operation mode selector. Turn the operation mode selector with screw driver. Operation mode is shown up through the window above the ...
Page 13
CAUTIONS 1. Terminal connections 1) Refer to wiring diagram before termi- nal connections. 2) Use the screw terminal type for flush mounting. For using 8 pin type, use the timer with screw terminal socket (AT8-RR pin cap (AD8-RC). ...
Page 14
Notes for PM4H series 2) Connections of non-contact input (open-collector) Apply the open-collector connection. The characteristics of the transistor used must be V =10V or more, I =10mA or CEO C more, and I =6µA or less. Additionally, CBO the ...