CES-A-BBA EUCHNER, CES-A-BBA Datasheet - Page 56

ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Solenoid
Non-Contact Safety Switches CES/CEM
Read head CEM-A-LH10R-S3
Dimension drawing
Notes on the electrical connection
Typical operating distance
Active
face
56
Adhesive force 1000 N
Without remanence
In combination with evaluation unit CES-A-ABA-01B/
CES-A-AEA.../CES-A-F1B-01B-AS1 and actuator CEM-A-BH10
Connection for external LED indicator
M8 plug connector
All the electrical connections must either be isolated from the mains supply by
a safety transformer according to EN/IEC 61558 with limited output voltage in
the event of a fault, or by other equivalent isolation measures.
If a common power supply is used, all the inductive and capacitive loads (e.g.
contactors) connected to the power supply must be connected to appropriate
interference suppression units.
Observe safe switch-off
distance s
internal component failure.
Safety outputs are safely
switched off.
6,5
ar
-4
= 20 mm on
With evaluation unit CES-A-AEA... and CES-A-ABA-01B
38
-3
38
OFF
8
-2
s
S1: Solenoid
operating voltage
connection
Center offset m [mm]
-1
Actuator
ON
Read head
m
4
3
2
1
0
Switch-off
distance
Hysteresis
Switch-on
distance S
ON
1
a0
S2: External LED indicator connection
2
ON
OFF
Output state
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
OFF
52
∅ 55
29
65
±0,15
3
S
a0
4
Hysteresis
Distance s
S3: Read
head
connection
Note
Notes on installation
Safety precautions
Direction of opening
The actuators and read heads CEM... can
only be used with the evaluation units given
above.
The plug connectors S1 and S3 are suitable
for snap-action and screw terminals.
The plug connector S1 does not have an
integrated LED.
For detailed information see the operating
instructions for the CES evaluation unit used.
The connection cable to the CES evaluation unit
must only be extended using EUCHNER plug
connectors and adequate consideration must be
given to EMC during assembly.
Intermediate terminals must not be used.
Actuator and read head must be fitted so
that:
The surface of the solenoid and the mating plate
may become hot.
Protection against accidental contact or adequa-
te heat dissipation must be provided by moun-
ting the read head on metal.
The safety switch CEM... with solenoid is not
allowed to be used for the protection of
personnel as per EN 1088.
They are positively connected to the safety
guard, e.g. by using safety screws.
When the safety door is opened, the
actuator is moved in the axial direction (fron-
tal) away from the read head.
± 4˚