SAF-XC878CM-16FFI Infineon Technologies, SAF-XC878CM-16FFI Datasheet - Page 109

MCU, 8BIT, 64K FLASH, 5V, 64LQFP

SAF-XC878CM-16FFI

Manufacturer Part Number
SAF-XC878CM-16FFI
Description
MCU, 8BIT, 64K FLASH, 5V, 64LQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of SAF-XC878CM-16FFI

Controller Family/series
XC800
Core Size
8bit
Program Memory Size
64KB
Ram Memory Size
3328Byte
No. Of Timers
4
No. Of Pwm Channels
10
Digital Ic Case Style
LQFP
Supply Voltage Range
4.5V To
Peripherals
ADC, PWM, Timer
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAF-XC878CM-16FFI 3V3 AA
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI 3V3 AC
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI 5V AA
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI 5V AA
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
SAF-XC878CM-16FFI 5V AC
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF-XC878CM-16FFI5VAC
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Data Sheet
CAN functionality according to CAN specification V2.0 B active.
Dedicated control registers are provided for each CAN node.
A data transfer rate up to 1 MBaud is supported.
Flexible and powerful message transfer control and error handling capabilities are
implemented.
Advanced CAN bus bit timing analysis and baud rate detection can be performed for
each CAN node via the frame counter.
Full-CAN functionality: A set of 32 message objects can be individually
– allocated (assigned) to any CAN node
– configured as transmit or receive object
– setup to handle frames with 11-bit or 29-bit identifier
– counted or assigned a timestamp via a frame counter
– configured to remote monitoring mode
Advanced Acceptance Filtering:
– Each message object provides an individual acceptance mask to filter incoming
– A message object can be configured to accept only standard or only extended
– Message objects can be grouped into 4 priority classes.
– The selection of the message to be transmitted first can be performed on the basis
Advanced Message Object Functionality:
– Message Objects can be combined to build FIFO message buffers of arbitrary
– Message objects can be linked to form a gateway to automatically transfer frames
Advanced Data Management:
– The Message objects are organized in double chained lists.
– List reorganizations may be performed any time, even during full operation of the
– A powerful, command driven list controller manages the organization of the list
– Message FIFOs are based on the list structure and can easily be scaled in size
– Static Allocation Commands offer compatibility with TwinCAN applications, which
Advanced Interrupt Handling:
– Up to 8 interrupt output lines are available. Most interrupt requests can be
– Message postprocessing notifications can be flexibly aggregated into a dedicated
frames.
frames or to accept both standard and extended frames.
of frame identifier, IDE bit and RTR bit according to CAN arbitration rules.
size, which is only limited by the total number of message objects.
between 2 different CAN buses. A single gateway can link any two CAN nodes. An
arbitrary number of gateways may be defined.
CAN nodes.
structure and ensures consistency of the list.
during CAN operation.
are not list based.
individually routed to one of the 8 interrupt output lines.
register field of 64 notification bits.