EP3C10M164C8N Altera, EP3C10M164C8N Datasheet - Page 108

IC CYCLONE III FPGA 402MHZ BGA-164

EP3C10M164C8N

Manufacturer Part Number
EP3C10M164C8N
Description
IC CYCLONE III FPGA 402MHZ BGA-164
Manufacturer
Altera
Series
Cyclone IIIr
Datasheets

Specifications of EP3C10M164C8N

No. Of Logic Blocks
645
Family Type
Cyclone III
No. Of I/o's
106
I/o Supply Voltage
3.3V
Operating Frequency Max
402MHz
Operating Temperature Range
0°C To +85°C
Family Name
Cyclone III
Number Of Logic Blocks/elements
10320
# I/os (max)
106
Frequency (max)
402MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
10320
Ram Bits
423936
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
164
Package Type
MBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C10M164C8N
Manufacturer:
ALTERA
0
6–8
Table 6–3. Selectable I/O Drivers for On-Chip Series Termination with and Without Calibration Setting (Part 2 of 2)
On-Chip Series Termination with Calibration
Cyclone III Device Handbook, Volume 1
SSTL-18 Class I
SSTL-18 Class II
HSTL-18 Class I
HSTL-18 Class II
HSTL-15 Class I
HSTL-15 Class II
HSTL-12 Class I
HSTL-12 Class II
I/O Standard
The Cyclone III device family supports on-chip series termination with calibration in
all banks. The on-chip series termination calibration circuit compares the total
impedance of the I/O buffer to the external 25-Ω ±1% or 50-Ω ±1% resistors
connected to the RUP and RDN pins, and dynamically adjusts the I/O buffer
impedance until they match (as shown in
The R
the I/O buffer.
Figure 6–2. Cyclone III Device Family On-Chip Series Termination with Calibration
OCT with calibration is achieved using the OCT calibration block circuitry. There is
one OCT calibration block in banks 2, 4, 5, and 7. Each calibration block supports each
side of the I/O banks. Because there are two I/O banks sharing the same calibration
block, both banks must have the same V
two related banks have different V
resides can enable OCT calibration.
On-Chip Series Termination with Calibration
S
shown in
Row I/O
50
25
50
25
50
25
50
Setting, in ohms (Ω)
Figure 6–2
Driver Series Termination
Cyclone III Device Family
Column I/O
is the intrinsic impedance of the transistors that make up
50
25
50
25
50
25
50
25
V
GND
CCIO
CCIO
R
R
S
S
s, only the bank in which the calibration block
CCIO
Figure
On-Chip Series Termination Without Calibration
Chapter 6: I/O Features in the Cyclone III Device Family
if both banks enable OCT calibration. If
Z
6–2).
O
Row I/O
50
25
50
25
50
25
50
Setting, in ohms (Ω)
Receiving
© December 2009 Altera Corporation
Device
Column I/O
50
25
50
25
50
25
50
25
OCT Support

Related parts for EP3C10M164C8N