DP83848HSQ National Semiconductor, DP83848HSQ Datasheet - Page 48
DP83848HSQ
Manufacturer Part Number
DP83848HSQ
Description
IC, TRANSCEIVER, ENET PHYTER, 40LLP
Manufacturer
National Semiconductor
Datasheet
1.DP83848HSQ.pdf
(80 pages)
Specifications of DP83848HSQ
Data Rate
100Mbps
No. Of Ports
1
Ethernet Type
IEEE 802.3u
Supply Current
92mA
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +125°C
Digital Ic Case Style
LLP
No. Of
RoHS Compliant
Interface Type
MII Serial, RMII
Rohs Compliant
Yes
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
www.national.com
7.2 Extended Registers
7.2.1 PHY Status Register (PHYSTS)
This register provides a single location within the register set for quick access to commonly accessed information.
Bit
15
14
13
12
11
10
9
8
7
6
Receive Error Latch
False Carrier Sense
Descrambler Lock
Page Received
Polarity Status
Signal Detect
Remote Fault
MDI-X mode
RESERVED
RESERVED
Bit Name
Latch
Table 21. PHY Status Register (PHYSTS), address 0x10
0, RO/LH
0, RO/LH
0, RO/LL
0, RO/LL
Default
0, RO
0, RO
0, RO
0, RO
0, RO
0, RO
RESERVED: Write ignored, read as 0.
MDI-X mode as reported by the Auto-Negotiation logic:
This bit will be affected by the settings of the MDIX_EN and
FORCE_MDIX bits in the PHYCR register. When MDIX is en-
abled, but not forced, this bit will update dynamically as the
Auto-MDIX algorithm swaps between MDI and MDI-X configu-
rations.
1 = MDI pairs swapped
0 = MDI pairs normal
Receive Error Latch:
This bit will be cleared upon a read of the RECR register.
1 = Receive error event has occurred since last read of RXERCNT
(address 0x15, Page 0).
0 = No receive error event has occurred.
Polarity Status:
This bit is a duplication of bit 4 in the 10BTSCR register. This bit will
be cleared upon a read of the 10BTSCR register, but not upon a
read of the PHYSTS register.
1 = Inverted Polarity detected.
0 = Correct Polarity detected.
False Carrier Sense Latch:
This bit will be cleared upon a read of the FCSR register.
1 = False Carrier event has occurred since last read of FCSCR (ad-
dress 0x14).
0 = No False Carrier event has occurred.
100Base-TX unconditional Signal Detect from PMD.
100Base-TX Descrambler Lock from PMD.
Link Code Word Page Received:
This is a duplicate of the Page Received bit in the ANER register,
but this bit will not be cleared upon a read of the PHYSTS register.
1 = A new Link Code Word Page has been received. Cleared on
read of the ANER (address 0x06, bit 1).
0 = Link Code Word Page has not been received.
RESERVED: Writes ignored, read as 0.
Remote Fault:
1 = Remote Fault condition detected (cleared on read of BMSR (ad-
dress 01h) register or by reset). Fault criteria: notification from Link
Partner of Remote Fault via Auto-Negotiation.
0 = No remote fault condition detected.
(Receive on TPTD pair, Transmit on TPRD pair)
(Receive on TRD pair, Transmit on TPTD pair)
48