LIS202DLTR STMicroelectronics, LIS202DLTR Datasheet - Page 27

ACCELEROMETER 2AXIS DGTL 14-LGA

LIS202DLTR

Manufacturer Part Number
LIS202DLTR
Description
ACCELEROMETER 2AXIS DGTL 14-LGA
Manufacturer
STMicroelectronics
Datasheet

Specifications of LIS202DLTR

Axis
X, Y
Acceleration Range
±2.3g, 9.2g
Sensitivity
18mg/digit, 72mg/digit
Voltage - Supply
2.16 V ~ 3.6 V
Output Type
Digital
Bandwidth
100Hz ~ 400Hz Selectable
Interface
I²C, SPI
Mounting Type
Surface Mount
Package / Case
14-LGA
Sensing Axis
X, Y
Acceleration
2 g, 8 g
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6071-2
LIS202DL
7.9
7.10
WU_CFG_1 (30h)
WU_SRC_1 (31h)
Table 29.
Table 30.
Table 31.
Table 32.
YH
YL
IA
AOI
res_1
res_2
YHIE
XHIE
YLIE
XLIE
AOI
--
LIR
Interrupt Active. Default value: 0
(0: no interrupt has been generated; 1: one or more interrupts have been generated)
Y High. Default value: 0
(0: no interrupt, 1: YH event has occurred)
Y Low. Default value: 0
(0: no interrupt, 1: YL event has occurred)
Register (30h)
Register description (30h)
Register (31h)
Register description (31h)
And/Or combination of Interrupt events. Default value: 0
(0: OR combination of interrupt events; 1: AND combination of interrupt events)
Latch Interrupt request into WU_SRC_1 reg with the WU_SRC_1 reg cleared by
reading WU_SRC_1 reg. Default value: 0
(0: interrupt request not latched; 1: interrupt request latched)
Reserved at Value: 0. Value should not be changed.
Reserved at Value: 0. Value should not be changed.
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
LIR
IA
res_1
--
res_2
--
YHIE
YH
YLIE
YL
Register description
XHIE
XH
XLIE
XL
27/36

Related parts for LIS202DLTR