STCN75M2E STMicroelectronics, STCN75M2E Datasheet - Page 12

IC TEMP SENSOR DIGITAL SO-8

STCN75M2E

Manufacturer Part Number
STCN75M2E
Description
IC TEMP SENSOR DIGITAL SO-8
Manufacturer
STMicroelectronics
Datasheet

Specifications of STCN75M2E

Featured Product
STM32 Cortex-M3 Companion Products
Function
Temp Sensor, Watchdog
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire, I2C)
Digital Output - Number Of Bits
9 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Ic Output Type
Digital
Sensing Accuracy Range
± 0.5°C
Temperature Sensing Range
-55°C To +125°C
Supply Current
125µA
Supply Voltage Range
2.7V To 5.5V
Sensor Case Style
SOIC
No. Of Pins
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STCN75M2E
Manufacturer:
ST
0
Operation
2.3
2.4
12/37
Comparator mode
In comparator mode, each time a temperature-to-digital (T-to-D) conversion occurs, the new
digital temperature is compared to the value stored in the T
tolerance number of consecutive temperature measurements are greater than the value
stored in the T
For example, if the FT1 and FT0 bits are equal to “10” (fault tolerance = 4), four consecutive
temperature measurements must exceed T
OS/INT output is active, it will remain active until the first time the measured temperature
drops below the temperature stored in the T
inactive state.
Putting the device into shutdown mode does not clear OS/INT in comparator mode.
Interrupt mode
In interrupt mode, the OS/INT output becomes active when the measured temperature
exceeds the T
bits (FT1, FT0) value in the configuration register. Once activated, the OS/INT can only be
cleared by reading from any register (temperature, configuration, T
device. Once the OS/INT has been deactivated, it will only be reactivated when the
measured temperature falls below the T
the FT value. This mode is better suited for interrupt driven microprocessor based systems.
OS
OS
value a consecutive number of times as determined by the fault tolerance
register, the OS/INT output will be asserted.
Doc ID 13307 Rev 8
HYS
OS
HYS
value a consecutive number of times equal to
to activate the OS/INT output. Once the
register, whereupon it will reset to its
OS
and T
OS
HYS
, or T
registers. If a fault
HYS
) on the
STCN75

Related parts for STCN75M2E