L300 Protek, L300 Datasheet - Page 11

Bench Top Power Supplies 300WATT PROG ELECT LOAD

L300

Manufacturer Part Number
L300
Description
Bench Top Power Supplies 300WATT PROG ELECT LOAD
Manufacturer
Protek
Datasheet

Specifications of L300

Output Current (channel 1)
30 A
Output Voltage (channel 1)
0 VAC to 360 VAC
Input Voltage
120 V to 220 V
Number Of Outputs
1
Output Voltage (1)
0 VAC to 360 VAC
Output Current (1)
30 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L3000
Manufacturer:
ST
Quantity:
6 200
Part Number:
L3000
Manufacturer:
ST
0
Part Number:
L3000-5D
Manufacturer:
ST
0
Part Number:
L3000-5D1
Manufacturer:
VISHAY
Quantity:
10
Part Number:
L3000-5D1
Manufacturer:
ST
0
Part Number:
L3000-5D1
Manufacturer:
ST
Quantity:
20 000
Part Number:
L3000-5D2
Manufacturer:
ST
0
Part Number:
L3000-5D2
Manufacturer:
ST
Quantity:
20 000
Part Number:
L3000-E3
Manufacturer:
ST
0
Part Number:
L3000N R11AC
Manufacturer:
INTEL
Quantity:
5
Part Number:
L3000S
Manufacturer:
ST
Quantity:
5 510
Part Number:
L3000S
Manufacturer:
DTL
Quantity:
5 510
2.3.3 R-set (set up a constant resistance)
2.3.4 Store data function
Procedure.
Step 1
Procedure
Step 1
Step 2
Step 3
Step 4
used continuously or are not changed. It may be desirable to use the Store Data Function.
This function stores Current, power and resistance settings in memory for later use. Ten
sets of values may be stored in the L300 memory with a location number assigned to it .
To exit the P- set screen press the ESC button
L300 electronic load can be setup for a constant resistance.
Constant resistance setup procedure is as following:
If you have and application that requires Current, Resistance power values that are
Press “ Store ” button
Press “ R-set ”
Enter the password ( Or jump to step 4 if the
Keyboard is unlocked)
Press “ OK ” button ( it will return to step 2 if
your password is entered wrong)
Press “ R-set ” to enter the original value
which is displayed on the LCD, or enter a
new value using the numeric key pad or
rotate “ Rotary SW ” to adjust the power to a
new value and then press the “ R-set ” button
to enter the new value
Operation description
Operation details
11
****V
****A
LCD display
SET RISIS = 200.0Ω
NEW=
ENTER PASWORD
ENTER PASWORD
ET RISIS = 200.0 Ω
NEW=
LCD display
****W
50.0
**