G5CA-1A4-DC24 Omron, G5CA-1A4-DC24 Datasheet - Page 2

General Purpose / Industrial Relays Sealed SPST-NO 24VDC

G5CA-1A4-DC24

Manufacturer Part Number
G5CA-1A4-DC24
Description
General Purpose / Industrial Relays Sealed SPST-NO 24VDC
Manufacturer
Omron
Series
G5CAr
Datasheets

Specifications of G5CA-1A4-DC24

Coil Resistance
2880 Ohms
Contact Form
SPST - NO
Coil Voltage
24 VDC
Contact Rating
10 A at 250 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
10 A
Coil Type
Non-Latching
Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Current, Rating
10 A
Function
Power
Mounting Type
PCB
Number Of Pins
4
Power, Rating
2500⁄300 VA⁄W
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Subminiature Dimensions
16 × 22 × 11 mm (L × W × H)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5CA-1A4-DC24V
Quantity:
12 000
G5CA
Note:
• The following UL-, CSA-, and EN/TÜV-certifying ratings differ from the performance characteristics of the individual models.
UL Standard: UL508 (File No. E41515)
2
Contact form
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time
Insulation resistance (See note 4.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Failure rate P standard
(Reference value: See note 5.)
Ambient temperature
Ambient humidity
Weight
G5CA
Model
Contact Ratings
Characteristics
Approved Standards
1. The data shown above are initial values.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method.
3. Measurement conditions: The value in parentheses indicates the operate time for high-sensitivity types.
4. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
5. This value is for a switching frequency of 120 operations/minute.
Item
1
No. of
poles
3 to
100 VDC
rating
Single
Silver alloy (cadmium-free)
10 A at 250 VAC;
10 A at 30 VDC
10 A
250 VAC, 125 VDC
10 A
2,500 VA, 300 W
Coil
Resistive load
15 A, 125 VAC
(General purpose)
10 A, 250 VAC
(General purpose)
15 A, 250 VAC
(Resistive)
10 A, 30 VDC
(Resistive)
Contact rating
Standard
30 m Ω max. (Quick-connect terminals type: 100 m Ω max.)
10 ms max. (15 ms max.)
10 ms max.
1,000 M Ω min.
2,500 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
4,500 V (1.2 x 50 µs)
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:
Malfunction:
Mechanical:
Electrical:
5 VDC, 100 mA
Operating: − 25°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 8 g (for TP model: Approx. 9.6 g)
3 A at 250 VAC;
3 A at 30 VDC
750 VA, 90 W
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
100,000
1,000 m/s
200 m/s
operations
20,000,000 operations min. at 18,000 operations/hr
300,000 operations min. (100,000 operations min. for Fully sealed Type)
at 1,200 operations/hr under resistive load of 10 A at 250 VAC;
100,000 operations min. under resistive load of 15 A at 110 VAC for high-capacity models
100,000 operations min. at 1,200 operations/hr under resistive load of 10 A at 30 VDC
No. of
2
10 A at 250 VAC;
10 A at 30 VDC
10 A
10 A
2,500 VA, 300 W
2
Resistive load
CSA Standard: CSA C22.2 No.14
(File No. LR31928)
EN Standard/TÜV Certificated:
EN61810-1 (Certification No. R50030053)
G5CA
G5CA
High-sensitivity
Model
Model
3 A at 250 VAC;
3 A at 30 VDC
750 VA, 90 W
Inductive load
1
1
(cos φ = 0.4,
L/R = 7 ms)
No. of
No. of
poles
poles
3 to
100 VDC
3, 5, 6, 12,
24, 48
VDC
rating
rating
Coil
Coil
15 A at 110 VAC;
10 A at 30 VDC
15 A
15 A
2,500 VA, 300 W
Resistive load
High-capacity, or quick-connect
15 A, 125 VAC
(General purpose)
10 A, 250 VAC
(General purpose)
15 A, 250 VAC
(Resistive)
10 A, 30 VDC
(Resistive)
15 A, 125 VAC
(cos φ = 1.0)
15 A, 250 VAC
(cos φ = 1.0)
10 A, 30 VDC
(0 ms)
Contact rating
Contact rating
terminals
5 A at 110 VAC;
3 A at 30 VDC
750 VA, 90 W
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
operations
100,000
100,000
operations
G5CA
No. of
No. of