G5CA-1A4-DC24 Omron, G5CA-1A4-DC24 Datasheet

General Purpose / Industrial Relays Sealed SPST-NO 24VDC

G5CA-1A4-DC24

Manufacturer Part Number
G5CA-1A4-DC24
Description
General Purpose / Industrial Relays Sealed SPST-NO 24VDC
Manufacturer
Omron
Series
G5CAr
Datasheets

Specifications of G5CA-1A4-DC24

Coil Resistance
2880 Ohms
Contact Form
SPST - NO
Coil Voltage
24 VDC
Contact Rating
10 A at 250 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
10 A
Coil Type
Non-Latching
Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Current, Rating
10 A
Function
Power
Mounting Type
PCB
Number Of Pins
4
Power, Rating
2500⁄300 VA⁄W
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Subminiature Dimensions
16 × 22 × 11 mm (L × W × H)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5CA-1A4-DC24V
Quantity:
12 000
Flat Relays that Switch 10-A/15-A Loads
with New Quick-connect Terminals
• Ideal for switching power in household appliances or for
• Subminiature dimensions: 16 x 22 x 11 mm (L x W x H).
• High-sensitivity models available with low power
• UL recognized / CSA certified.
• Fully sealed models and quick-connect terminal models
• RoHS Compliant.
Ordering Information
To order: Select the part number and add the rated coil voltage to the part number. Example: G5CA-1A4-H DC12.
Note: 1. Contact your OMRON representative for details on other coil voltage specifications.
■ Model Number Legend
1. Number of Poles
Enclosure
Ratings
Flux protection
Fully sealed
G5CA-1A
outputs from industrial devices.
consumption (150 mW).
available (#187 load contact terminals).
PCB Relay
G5CA
1A: 1 pole (SPST-NO)
2. High-capacity models with a fully sealed structure are not available.
3. Standard or high-sensitivity models with quick-connect terminals are not available.
1 2 3 4 5
Item
-
Contact
configuration
SPST-NO
-
-
2. Enclosure Ratings
3. Terminal form
None: Flux protection
4:
None: PCB terminal
TP:
Standard
G5CA-1A
G5CA-1A4
Fully sealed
Quick-connect terminal (#187)
G5CA-1A-H
G5CA-1A4-H
High-sensitivity
4. Special functions
5. Coil consumption
None: Standard
E:
None: Standard
H:
High-capacity
High-sensitivity
Model
High-capacity
G5CA-1A-E
---
Standard Specifications
Contact Configuration:SPST-NO
Enclosure Ratings:
Terminal form:
PCB Relay
Quick-connect terminals
(#187)
G5CA-1A-TP-E
---
G5CA
Flux protection
PCB terminal
185

G5CA-1A4-DC24 Summary of contents

Page 1

... UL recognized / CSA certified. • Fully sealed models and quick-connect terminal models available (#187 load contact terminals). • RoHS Compliant. Ordering Information To order: Select the part number and add the rated coil voltage to the part number. Example: G5CA-1A4-H DC12. Item Enclosure Contact Standard ...

Page 2

... Rated load 250 VAC VDC Rated carry current 10 A Max. switching voltage 250 VAC, 125 VDC Max. switching current 10 A Max. switching power 2,500 VA, 300 W (reference value) G5CA 186 PCB Relay 12 VDC 24 VDC 5 VDC 16 720 Ω 2,880 Ω 167 Ω ...

Page 3

... EN Standard/TÜV Certificated: EN61810-1 (Certification No. R50030053) Model No. of Coil No. of poles rating operations G5CA 100,000 12, 24, 48 VDC No. of operations 100,000 Contact rating No. of operations 15 A, 125 VAC 100,000 (cosφ 250 VAC (cosφ VDC L (– ms) R G5CA 187 PCB Relay ...

Page 4

... DC inductive load AC inductive G5CA-1A 0.3 load G5CA-1A-E G5CA-1A (L/R=7 ms) (cos φ=0.4) 0 100 300 500 1,000 Switching voltage (V) Operating Temperature vs. Must-operate/Must-release Voltage 100 Sample: G5CA-1A DC No. of samples: 5 Must-operate voltage Must-release voltage 80 max min. 40 max. X min −40 − Ambient temperature (˚C) Note: The " ...

Page 5

... The G5CA is a power relay designed for applications switching power loads such as heaters in electric household appliances. Do not use the G5CA to switch micro loads less than 100 mA, such as in signal applications. • Use fully sealed models if the relays will require washing. Flux-pro- tection models may malfunction or the relay's performance may be otherwise adversely affected if cleaning fluid enters the relay ...

Page 6

... MEMO G5CA 190 PCB Relay ...

Page 7

... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. PCB Relay G5CA ...

Page 8

... E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 06/09 Cat. No. X301-E-1 G5CA PCB Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...