MAX34440ETL+ Maxim Integrated Products, MAX34440ETL+ Datasheet - Page 35

Supervisory Circuits PMBUS 6-CH POW SUPPLY MANAGER

MAX34440ETL+

Manufacturer Part Number
MAX34440ETL+
Description
Supervisory Circuits PMBUS 6-CH POW SUPPLY MANAGER
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX34440ETL+

Minimum Operating Temperature
- 40 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current (typ)
2.5 mA
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Package / Case
TQFN-40
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MFR_MODE command is used to configure the device to support manufacturer specific commands. The MFR_
MODE command is described in Table 21.
Table 21. MFR_MODE
Note: V
while power supplies are being sequenced.
10:9
BIT
5:0
15
14
13
12
11
8
7
6
DD
must be above 2.9V for the device to clear or log data into MFR_NV_FAULT_LOG. MFR_MODE should not be changed
FORCE_NV_FAULT_LOG
CLEAR_NV_FAULT_LOG
PSEN_PP_OD
SOFT_RESET
PSEN_HI_LO
PGTIME[1:0]
PMBus 6-Channel Power-Supply Manager
BIT NAME
ALERT
0
0
0
Setting this bit to 1 forces the device to log data into the nonvolatile fault log. Once set, the
device clears this bit when the action is completed. The host must set again for subsequent
action. If an error occurs during this action, the device sets the CML bit in STATUS_BYTE
and STATUS_WORD; no bits are set in STATUS_CML.
Setting this bit to 1 forces the device to clear the nonvolatile fault log by writing FFh to all
byte locations. Once set, the device clears this bit when the action is completed. The host
must set again for subsequent action. If an error occurs during this action, the device sets
the CML bit in STATUS_BYTE and STATUS_WORD; no bits are set in STATUS_CML.
0 = ALERT disabled (device does not respond to ARA).
1 = ALERT enabled (device responds to ARA and ARA must be used).
This bit always returns a 0.
This bit must be set, then cleared and set again within 8ms for a soft reset to occur.
This bit always returns a 0.
Applies to all PSEN outputs.
0 = PSEN push-pull output.
1 = PSEN open-drain output.
Applies to all PSEN outputs.
0 = PSEN active low.
1 = PSEN active high.
These bits always return a 0.
PGTIME1
0
0
1
1
PGTIME0
0
1
0
1
MEANING
TIME FROM POWER GOOD DETERMINED
UNTIL PG OUTPUT IS ASSERTED (ms)
Immediately
1000
100
500
MFR_MODE (D1h)