MAX34440ETL+ Maxim Integrated Products, MAX34440ETL+ Datasheet - Page 24

Supervisory Circuits PMBUS 6-CH POW SUPPLY MANAGER

MAX34440ETL+

Manufacturer Part Number
MAX34440ETL+
Description
Supervisory Circuits PMBUS 6-CH POW SUPPLY MANAGER
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX34440ETL+

Minimum Operating Temperature
- 40 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current (typ)
2.5 mA
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Package / Case
TQFN-40
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The OPERATION command is used to turn the power supply on and off in conjunction with the CONTROL input pin. The
OPERATION command is also used to cause the power supply to set the output voltage to the upper or lower margin
voltages. The power supply stays in the commanded operating mode until a subsequent OPERATION command or
until a change in the state of the CONTROL pin (if enabled) instructs the power supply to change to another state. The
valid OPERATION command byte values are shown in Tables 8 and 9. The OPERATION command controls how the
device responds when commanded to change the output. When the command byte is 00h, the device immediately
turns the power supply off and ignores any programmed turn-off delay. When the command byte is set to 40h, the
device powers down according to the programmed turn-off delay. In Tables 8 and 9, “act on any fault” means that if
any warning or fault on the selected power supply is detected when the output is margined, the device treats this as a
warning or fault and responds as programmed. “Ignore all faults” means that overvoltage, overcurrent, and undervolt-
age warnings and faults on the selected power supply are ignored and not reported. Any command value not shown
in Tables 8 and 9 is an invalid command. If the device receives a data byte that is not listed in Tables 8 and 9, then
it treats this as invalid data, declares a data fault (set CML bit and assert ALERT), and responds as described in the
Fault Management and Reporting section.
USER NOTE: All power supplies tagged as GLOBAL supplies (see MFR_FAULT_RESPONSE) should be turned
on and off at the same time.
PMBus 6-Channel Power-Supply Manager
Table 8. OPERATION Command Byte (When Bit 3 of ON_OFF_CONFIG = 1)
Note: The VOUT of all enabled channels must exceed POWER_GOOD_ON for margining to begin.
Note: The device only takes action if the supply is enabled. The VOUT of all enabled channels must exceed POWER_GOOD_ON
for margining to begin.
24
Table 9. OPERATION Command Byte (When Bit 3 of ON_OFF_CONFIG = 0)
COMMAND BYTE
COMMAND BYTE
A4h
A8h
A4h
A8h
00h
40h
80h
94h
98h
00h
40h
80h
94h
98h
Immediate Off (No Sequencing)
POWER SUPPLY ON OR OFF
POWER SUPPLY ON OR OFF
Soft Off (with Sequencing)
Command Has No Effect
Command Has No Effect
Command Has No Effect
Command Has No Effect
Command Has No Effect
Command Has No Effect
Command Has No Effect
On
On
On
On
On
Margin High (Act On Any Fault)
Margin High (Act On Any Fault)
Margin Low (Act On Any Fault)
Margin Low (Act On Any Fault)
Margin High (Ignore All Faults)
Margin High (Ignore All Faults)
Margin Low (Ignore All Faults)
Margin Low (Ignore All Faults)
MARGIN STATE
MARGIN STATE
Margin Off
Margin Off
N/A
N/A
N/A
N/A
OPERATION (01h)