D2MQ-1L Omron, D2MQ-1L Datasheet - Page 2

LEAF LEVER SPDT 2.1OZ/500MA

D2MQ-1L

Manufacturer Part Number
D2MQ-1L
Description
LEAF LEVER SPDT 2.1OZ/500MA
Manufacturer
Omron
Series
D2MQr
Type
Snap Actionr
Datasheets

Specifications of D2MQ-1L

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
0.5A @ 30VDC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Solder Lug
Operating Force
60gf
Contact Form
SPDT
Contact Rating
0.5 Amp at 30 Volts
Actuator
Lever, Leaf
Microswitch Type
Ultra Subminiature
Actuator Style
Leaf Lever
Operating Force Max
60gf
Contact Voltage Dc Nom
30V
Contact Current Max
500mA
Switch Terminals
Through Hole
Circuitry
SPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D2MQ1L
SW146
D2MQ
Specifications
Note:
Note:
2
Contact
Minimum applicable load
30 VDC
Operating speed
(see note 2)
Operating frequency
Insulation resistance
Contact resistance
(initial value)
Dielectric strength
Vibration resistance
(see note 3)
Shock resistance
(see note 3)
Durability (see note 4)
Degree of protection
Degree of protection against
electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
Ratings
Characteristics
Contact Specifications
Rated voltage
The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
1. The data given above are initial values.
2. The values are for the pin plunger models. (For different models, consult your OMRON sales representative.)
3. Malfunction: 1 ms max.
4. For testing conditions, consult your OMRON sales representative.
Rating
Specification
Material
Gap (standard
value)
Rivet
Silver plated
0.15 mm
50 mA
at 5 VDC
Type
Item
0.5 A
0.1 mm to 0.5 m/s
Mechanical: 60 operations/min max.
Electrical:
100 MΩ min. (at 250 VDC)
100 mΩ max.
500 VAC, 50/60 Hz for 1 min between terminals at the same polarity
500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 2)
Destruction: 1,000 m/s
Malfunction: 300 m/s
Mechanical: 30,000 operations min. (60 operations/min)
Electrical:
IEC IP40
Class I
175
–15°C to 70°C (at ambient humidity of 60% max.) (with no icing or condensation)
35% to 85% (for 5°C to 35°C)
Approx. 0.3 g
0.5 A
Gold plated
5 mA at 5 VDC
30 operations/min max.
10,000 operations min. (30 operations/min)
0.5 A
50 mA
2
{approx. 30G} max.
2
Resistive load
{approx. 100G} max.
50 mA
Contact Form
50 mA
SPDT
D2MQ