A165-TRM-1 Omron, A165-TRM-1 Datasheet - Page 24

SWITCH PB ROUND MOM SPDT RED

A165-TRM-1

Manufacturer Part Number
A165-TRM-1
Description
SWITCH PB ROUND MOM SPDT RED
Manufacturer
Omron
Series
A16r
Type
Standardr
Datasheet

Specifications of A165-TRM-1

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 125VAC
Actuator Type
Round Button
Mounting Type
Panel Mount
Termination Style
Solder, Quick Connect - .110" (2.8mm)
Contact Form
SPDT
Contact Rating
5 Amps at 125 Volts
Actuator
Round
Mounting Style
Snap In
Illumination
Not Illuminated
Body Shape
Square
Dielectric Strength
2000 Volts
Features
Terminal layout simplifies common wiring
Insulation Resistance
100 MOhms
Mounting Angle
Straight
Operating Force
4.91 N
Water / Moisture Rating
IP65
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A165TRM1
Z1326
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches.
Do not apply a voltage between the incandescent
lamp and the terminal that is greater than the rated
voltage. If the incandescent lamp is broken, the
operating part may pop out.
Always turn OFF the power and wait for 10 minutes
before replacing the incandescent lamp. If the lamp is
replaced immediately after the power is turned OFF,
the remaining heat may cause burns.
Mounting
Wiring
Operating Environment
• Always make sure that the power is turned OFF before mounting,
• Do not tighten the mounting nut more than necessary using tools
• Solder terminals and quick-connect terminals (#110) are commonly
• Be sure to use electrical wires that are a size appropriate for the
• Use non-corrosive resin fluid as the flux.
• Make sure that the electric cord is wired so that it does not touch
• After wiring the Switch, maintain an appropriate clearance and
• This Switch is intended for indoor use only. Using the Switch
• The IP65 model is designed with a degree of protection so that it
• Do not use the Switch submersed in oil or water, or in locations
removing, or wiring the Switch, or performing maintenance.
such as pointed-nose pliers. Doing so will damage the mounting
nut.
The tightening torque is 0.29 to 0.49 N·m.
used for terminals.
applied voltage and carry current (conductor size is 0.5 to 0.75
mm
below. If the soldering is not properly performed, the lead wires will
become detached, resulting in short-circuits.
the Unit. If the electric cord touches the Unit, then electric wires with
a heat resistance of 100°C min. must be used.
creepage distance.
outdoors will cause the Switch to fail. If IP40 models are used in
locations subject to dust, metallic particles, or oil, be careful that
none of these penetrates the Switch.
will not sustain damage if it is subjected to water from any direction
to the front of the panel.
continuously subject to splashes of oil or water. Doing so may result
in oil of water entering the Switch.
1. Hand soldering: 350°C, within 3 s
2. Dip soldering: 350°C, within 3 s
Wait for one minute after soldering before exerting any external
force on the solder.
2
). Perform soldering according to the conditions provided
Precautions for Correct Use
WARNING
Using the Microload
LED
Others
• Insert a contact protection circuit, if necessary, to prevent the
• The A16 allows both a standard load (125 V at 5A, 250 V at 3 A)
• The minimum applicable load is the N-level reference value. This
• The LED current-limiting resistor is built-in, so external resistance
• The oil-resistant IP65 uses NBR rubber and is resistant to general
• The durability of the Switch depends in the switching conditions.
• If the panel is to be finished with coating, etc., make sure that the
• Do not subject the Switch to extreme shock or vibration. Doing so
• Do not let sharp objects come into contact with the Switches that
Rated voltage
12 VAC/VDC
24 VAC/VDC
reduction of life expectancy due to extreme wear on the contacts
caused by loads where inrush current occurs when the contact is
opened and closed.
and a microload. If a standard load is applied, however, the
microload area cannot be used. If the microload area is used with a
standard load, the contact surface will become rough, and the
opening and closing of the contact for a microload may become
unreliable.
value indicates the malfunction reference level for the reliability
level of 60% (λ 60) (conforming to JIS C5003).
The equation, λ 60 = 0.5 × 10
estimated malfunction rate is less than 1/2,000,000 operations with
a reliability level of 60%.
is not required.
cutting oil and cooling oil. Some particular oils cannot be used with
the oil-resistant IP65, however, so contact your OMRON
representative for details.
Always test the Switch under actual application conditions to
confirm applicability and use the Switch only for the number of
switching operations that will not affect performance.
Continuing to use the Switch with degraded performance will
eventually result insulation faults between circuits, burning of the
Switch, or other failures.
panel meets the specified dimensions after the coating.
will cause malfunctions and damage to the Switch.
are made of resin. Doing so will damage the Switches, causing
scratches on the outside of the operating parts, and malfunction.
When handling the Switches, do not throw or drop them.
5 VDC
30
12
24
5
0
0.1
Red, yellow, white: 300 Ω
Green, blue, pure white: 160 Ω
Red, yellow, white: 1 kΩ
Green, blue, pure white: 910 Ω
2.4 kΩ
0.15 mA
Invalid
area
1 mA
1
Internal limiting resistor
Microload area
-4
/operations indicates that the
10
100
Current (mA)
1,000
A16
24

Related parts for A165-TRM-1