BGA-3528 OKI METCAL, BGA-3528 Datasheet - Page 12

no-image

BGA-3528

Manufacturer Part Number
BGA-3528
Description
ASSEMBLY MICRO-OVEN 3500 SERIES
Manufacturer
OKI METCAL
Series
3500r
Datasheet

Specifications of BGA-3528

Accessory Type
Oven
For Use With/related Products
BGA and CSP Rework systems
Other names
BGA3528
10
Camera Features (not shown)
• YC Out (SVHS Video) Output Connector- When using a high resolution monitor, connect one end of the
• Power Supply Connector - Insert the 12V connector extending from the rear of the BGA/CSP-3500
• Video Out Connector - If using a monitor without SVHS capability, connect one end of the video cable
IV. SET-UP PROCEDURES
Prior to performing initial set-up, unpack all accessories from shipping containers. Check that your
BGA/CSP-3500 has arrived complete by verifying all of the accessories listed in Section II have been
included. After all components are located, begin setup.
Placement Section
IMPORTANT: There is a transportation screw located on the bottom of the placement arm and on the tool-
ing plate/component slide to stop these parts from moving during transportation. Completely loosen or
remove these screws prior to operation to allow these parts to move freely without any restrictions.
When setting up this equipment, be sure to arrange it in a position that allows the user to operate this
machine in a comfortable, well-spaced environment.
1. Remove the BGA/CSP-3500 Main Unit, Control Unit, Camera, 20” High-Resolution Monitor (optional)
2. Mount the camera to the lens by rotating the camera clockwise so that it fully screws onto the top of
3. Connect the black cable extending from the rear of the BGA/CSP-3500 base unit to the connector
4. Connect one end of the appropriate video cable (SVHS or BNC) to the appropriate video output
5. Connect the 5 pin female connector extending from the FS-24 footswitch to the corresponding 5 pin
6. Select the medium vacuum pipette and attach it to the vacuum shaft of the Placement Head.
IMPORTANT: Every BGA/CSP-3500 Rework System has been factory calibrated.
Recalibration may be required after initial setup due to shipping or rough handling. Verifying calibration is
strongly recommended prior to initial use. This procedure is thoroughly discussed later in the manual in the
section titled “Calibration Proceedure.”
Reflow Section
IMPORTANT: Prior to initial setup of your BGA/CSP-3500, please remove the transportation screw located on
the bottom of the BGA-3500 Series Control Unit. Tilt the unit on its side and remove the screw with a
Phillips-head screwdriver.
and all accessories from there shipping containers.
the lens assembly.
marked “12VDC IN” located on the rear of the camera.
connector (“Y/C Out” for SVHS or “Video Out” for standard video) on the rear of the camera. Connect
the other end to the correct input on the rear of the monitor.
male connector located on the rear of the BGA/CSP-3500 Main Unit.
SVHS cable into this receptacle and the other end to the “SVHS In” receptacle located in the
rear of the monitor.
Main Unit into this receptacle.
to this female BNC receptacle and the other to the monitor’s “Video In” connector
BGA-3500 Series Manual 5/01