Specifications of PSE531-M5

Pressure Type
Vacuum
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Female, 0.8" (20.32mm) NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Package / Case
Cylinder, Metal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1020
Option
When only optional parts are required, order using the part
numbers listed below.
Specifications
16-3-4
Rated pressure range
Proof pressure
Fluid
Power supply voltage
Current consumption
Output specification
Accuracy
Linearity
Repeatability
Power supply voltage effect
Temperature characteristics (Based on 25°C)
Port size
Material
Sensor cable/Option
Connector
Sensor cable
Connector +
Sensor cable
Description
Enclosure
Temperature range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Model
Pressure Sensor
Series
ZS-26-E
ZS-26-G
ZS-26-F
Part no.
0
1
2
3
Compound pressure [–101 to 101 kPa]
10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s
Pressure sensing range
The connector is not connected to
the cable at the time of shipment.
Low pressure [0 to 101 kPa]
High pressure [0 to 1 MPa]
Vacuum [0 to –101 kPa]
Cable length: 3 m
Cable length: 3 m
PSE530-M5
0 to 1 MPa
4 pcs. per set
1.5 MPa
PSE53 0
Body: Stainless steel Grade 303, Internal enclosure: PPE; Pressure sensor: Silicon; O-ring: NBR
Note
±2% F.S. or less based on the analog output value at 25°C from a range of 0° to 50°C
±1% F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC
±2% F.S. or less (Within rated pressure range, Ambient temperature 25° ±3°C)
PSE530
1000 VAC, 50/60Hz for 1 minute between external terminals and case
0° to 50°C; Stored: –10° to 70°C (No freezing or condensation)
How to Order
Halogen-free heavy-duty cord, ø2.7, 0.15 mm
M5
980 m/s
Analog output (1 to 5 V, Output impedance: Approx. 1 kΩ)
5 MΩ between external terminals and case (at 50 VDC)
Port size
0 to –101 kPa
M5 x 0.8
PSE531-M5
2
in X, Y, Z directions, 3 times each (De-energized)
12 to 24 VDC (Ripple ±10% or less)
M5
Air/Non-corrosive gas
±1% F.S. or less
±1% F.S. or less
15 mA or less
M5 x 0.8
IP40
2
acceleration, in X, Y, Z directions, for 2 hours each (De-energized)
Note) At the factory, the connector is not connected to the
Option
Nil
CL
L
cable, but packed together with it for shipment.
PSE532-M5
0 to 101 kPa
Sensor cable (3 m)
Sensor cable (3 m) + Connector (1 pc.)
500kPa
2
, 3 cores, 3 m
Connector
Without cable
–101 to 101 kPa
PSE533-M5

Related parts for PSE531-M5

PSE531-M5 Summary of contents

Page 1

... PSE530 How to Order M5 Port size 0.8 Note PSE531- –101 kPa Air/Non-corrosive gas VDC (Ripple ±10% or less less Analog output ( Output impedance: Approx. 1 kΩ) ±2% F.S. or less (Within rated pressure range, Ambient temperature 25° ±3°C) ±1% F.S. or less ±1% F.S. or less ± ...

Page 2

... Analog output ( Dimensions PSE53„-M5 3.4 With sensor cable Pressure Sensor Brown Black Blue Blue Black 29.4 0.5 27 5.5 PSE530 Series VDC Load M5 x 0.8 Pressure port 12 ZSE„ ISE„ PSE Z SE3 ZSP ISA2 IS„ ZSM PF2„ IF„ Data 16-3-5 ...

Page 3

... Incorrect wiring can damage the switch and cause a malfunction or erroneous switch output. Connections should be done while the power is turned off not attempt to insert or pull the pressure sensor or its connector when the power is on. Switch output may malfunction. 3. Wire separately from power lines and high voltage lines, avoiding wiring in the same conduit with these lines ...

Page 4

... Use a new sensor connector in case wiring or the snapping of A into B are done incorrectly • To connect the connector to the multi-channel pressure sensor, push the connector with its A portion facing toward you into the socket until it clicks as shown below. • To remove the connector, pull it straight out while applying pressure to the fingers on both sides ...

Page 5

... Specific Product Precautions 3 Be sure to read before handling. Wiring Caution 3. Connecting to other series • Any pressure sensor (SW) can be connected as long as it generates analog output ( signal. However, the pressure range must match. • SMC pressure sensors, Series PSE510 & PSE520, are also connectable. ...

Page 6

... When equipment removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc ...

Page 7

... Remove drainage from air filters regularly. (Refer to the specifications.) 4. Shut-down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on. 5. Start-up after maintenance and inspection Apply operating pressure and power to the equipment and check for proper operation and possible air leaks ...

Page 8

Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards “ISO 9001” and ...

Page 9

... This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. • Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 ...

Page 10

... CSA and UL Standards. í TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE Standard ...

Page 11

... SMC’s Global Service Network America U.S.A. SMC Corporation of America 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 317-899-4440 FAX: 317-899-3102 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 MEXICO SMC Corporation (Mexico), S.A. DE C.V. ...

Page 12

Europe FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC Pneumatics Norway A/S Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, Norway TEL: 67-12-90-20 FAX: 67-12-90-21 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. Nijverheidsstraat 20 B-2160 ...

Related keywords