Specifications of ISE40-T1-22

Pressure Type
Vacuum
Operating Pressure
1.45 PSI, 1 MPa
Port Size
Female, 1/8" (3.175mm) NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1005
ZSE40 ( F ) /ISE40–
Dimensions
16-2-24
Series
1. Immediately after supplying power, there is drift of about ±0.5% F.S. When used
2. Do not use in locations where there is splashing or spraying of oils and solvents.
3. When using a commercially available switching regulator, be sure to ground the
4. In locations where the switch is exposed to water and dust, etc., these may
with very low pressure, allow the unit to warm up for about 20 to 30 minutes.
FG terminal.
enter the switch from the atmospheric release port. Insert ø4 tubing (inside
diameter ø2.5) into the atmospheric release port, and extend the other end to a
safe area where water, etc., is not splashed or sprayed. Be sure that tubing is
not bent and holes are not blocked, etc., or it will become impossible to make
correct pressure measurements.
∗ For splash proof use (IP65), insert an air tube into the atmospheric release port.
Caution
(Refer to “Precautions” for details.)
ZSE40/ISE40
OUT1
32.3
SET
30
20
12
7.8
OUT2
MPa
C4
C6
M5
Atmospheric
release port
One-touch fitting ø4, ø6
For–M5
ø3.5
Precautions
12.8
M5 x 0.8 thread depth 5
8
OUT1
SET
OUT2
MPa
Recommended tubing (SMC)
Atmospheric release port
TU0425 (Polyurethane)
Air tube

Related parts for ISE40-T1-22