ISE30-T1-25 SMC Corporation of America, ISE30-T1-25 Datasheet - Page 3

no-image

ISE30-T1-25

Manufacturer Part Number
ISE30-T1-25
Description
SENSOR PRESSURE 1MPA NPT/M5F NPN
Manufacturer
SMC Corporation of America
Series
ISE30r
Datasheet

Specifications of ISE30-T1-25

Pressure Type
Vacuum
Operating Pressure
1.45 PSI, 1 MPa
Port Size
Female, 1/8" (3.175mm) NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1000
Initial Setting
If the unit specification indicated at the time of ordering is “M”,
the fixed SI unit will be used. If it is Nil, refer to “Unit Switching
Function” on page 16-2-8.
Setting
Initial setting mode
Press and hold the SET button for 2 seconds or longer.
Display monitor will be per Figure A below, and the switch
will now be in the display color setting mode.
16-2-6
Series
2.
1.
(Standard: Factory setting) (Reversed)
ON
OFF
Display color setting
Select the color for LCD display.
Press the
Press the SET button to set the color and proceed to the
operating mode setting.
If the analog output is set, press the
and select the desired display color from
(Red). Press the SET button to exit this mode and return to
the measuring mode.
This mode will let you select the switch operating mode.
While the current operating mode is displayed, press the
Operating mode setting
Press the SET button to set the mode and proceed to the
output type setting.
UP or
Measuring
Hysteresis
Hysteresis mode
(H)
mode
OUT
OUT
OUT
ON/OFF: Red
P1
ON: Red
PRESSURE
PRESSURE
DOWN button to select a newly desired operating
PRESSURE
ZSE30/ISE30
UP or
ON
OFF
Press the
and hold for 2 sec. or longer.
Hysteresis
Press the
DOWN button to choose a display color.
OUT
(H)
n1
Figure A
PRESSURE
SET
SET
(Standard: Factory setting)
ON
OFF
button
button.
Window comparator mode
Hysteresis
OUT
OUT
OUT
(H)
ON/OFF: Green
P1
ON: Green
PRESSURE
PRESSURE
PRESSURE
UP or
Hysteresis
Set the output type, response
time, and display color
switching.
Enter the set value of the
pressure to perform switch
output.
(H)
P2
Pressure setting
Initial setting
(Green) or
ON
OFF
DOWN button
Hysteresis
(H)
(Reversed)
n1
Hysteresis
(H)
n2
3.
4.
5.
Press the
Press the
Response time setting
The switch output response time can be set arbitrarily.
Chattering can be prevented with a response time setting.
While the current response time is displayed, press the
or
Press the SET button to set the response time and proceed
to the auto preset setting.
If the operating mode is the window comparator mode, press
the SET button to return to the measuring mode.
This function stores the measuring pressure that is set
during the auto preset mode as a basic value.
While the current setting is displayed, press the
Press the SET button to set the auto preset and return to the
measuring mode.
The type of switch output can be set arbitrarily.
While the current output type is displayed, press the
normally closed
Press the SET button to set the output type and proceed to
the response time setting.
Output type setting
Auto preset setting
OUT
DOWN button to switch between normally open
DOWN button to select it as an auto preset setting.
DOWN button to select a new response time.
PRESSURE
2.5 ms
SET
SET
OUT
OUT
Normally open
button.
button.
PRESSURE
Manual
PRESSURE
Detects and displays the pressure and
performs switch operations. Other functions
such as the value clear function can be set
according to the application purpose.
.
OUT
OUT
PRESSURE
PRESSURE
640 ms
20 ms
Measuring mode
Normally closed
OUT
OUT
PRESSURE
PRESSURE
Auto
OUT
OUT
1280 ms
PRESSURE
160 ms
PRESSURE
UP or
and
UP