Specifications of XBP09-DPUIT-156

Frequency
902MHz ~ 928MHz
Data Rate - Maximum
156kbps
Modulation Or Protocol
FHSS
Applications
ISM
Power - Output
17dBm (50mW)
Sensitivity
-100dBm
Voltage - Supply
3 V ~ 3.6 V
Current - Receiving
80mA
Current - Transmitting
210mA
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1168
Special
Special Commands
Addressing
Addressing Commands
AT
Command
WR
RE
FR
AC
R1
VL
AT
Command
DH
DL
DD
SH
SL
HP
SE
DE
CI
NP
5. 900/DigiMesh Command Reference Tables
Name and Description
Write. Write parameter values to non-volatile memory so that parameter modifications
persist through subsequent resets.
Note: Once WR is issued, no additional characters should be sent to the module until
after the "OK\r" response is received.
Restore Defaults. Restore module parameters to factory defaults.
Software Reset. Reset module. Responds immediately with an “OK” then performs a
reset 100ms later.
Apply Changes. Immediately applies new settings without exiting command mode.
Restore Compiled. Restore module parameters to compiled defaults.
Version Long. Shows detailed version information including application build date and
time.
Name and Description
Destination Address High. Set/Get the upper 32 bits of the 64-bit destination address.
When combined with DL, it defines the destination address used for transmission.
Destination Address Low. Set/Get the lower 32 bits of the 64-bit destination address.
When combined with DH, DL defines the destination address used for transmission.
Device Type Identifier. Stores a device type value. This value can be used to
differentiate multiple XBee-based products.
Serial Number High. Read high 32 bits of the RF module's unique IEEE 64-bit
address. 64-bit source address is always enabled. This value is read-only and it never
changes
Serial Number Low. Read low 32 bits of the RF module's unique IEEE 64-bit address.
64-bit source address is always enabled. This is read only and it is also the serial
number of the node..
Hopping Channel.
Set/read the spread spectrum channel on which the module communicates. Separate
channels minimize interference between multiple networks operating in the same
vicinity.
Source Endpoint. Set/read the application layer source endpoint value. This value will
be used as the source endpoint for all data transmissions. The default value 0xE8 (Data
endpoint) is the Digi data endpoint
Destination Endpoint.
Set/read application layer destination ID value. This value will be used as the
destination endpoint for all data transmissions. The default value (0xE8) is the Digi data
endpoint.
Cluster Identifier.
Set/read application layer cluster ID value. This value will be used as the cluster ID for
all data transmissions. The default value 0x11 (Transparent data cluster ID)
Maximum RF Payload Bytes.
This value returns the maximum number of RF payload bytes that can be sent in a
unicast transmission based on the current configurations.
© 2009 Digi International, Inc.
Parameter Range
0 to 0xFFFFFFFF
0 to 0xFFFFFFFF
0-0xFFFFFFFF
[ read only ]
0-0xFFFFFFFF
0-0xFFFFFFFF
0-0x7 (standard variant)
0-0x3 (International
variant)
0-0xFF
0-0xFF
0-0xFFFF
0-0xFFFF
Parameter Range Default
--
--
--
--
--
--
--
--
--
--
--
--
Default
0
0x0000FFFF
0x40000
Factory
Factory
0
0xE8
0xE8
0x11
n/a
     35

Related parts for XBP09-DPUIT-156