XB24-BUIT-004 Digi International/Maxstream, XB24-BUIT-004 Datasheet - Page 63

no-image

XB24-BUIT-004

Manufacturer Part Number
XB24-BUIT-004
Description
MODULE 802.15.4 SER 2 U.FL CONN
Manufacturer
Digi International/Maxstream
Series
XBee™r
Datasheet

Specifications of XB24-BUIT-004

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
2 mW (3 dBm)
Sensitivity
-96dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
38mA
Current - Transmitting
35mA
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee ZNet 2.5/XBee‐PRO ZNet 2.5 ZigBee OEM RF Modules v1.x4x 
Identifies the UART data frame being reported.
Matches the Frame ID of the Remote Command
Request the remote is responding to.
Frame ID (Byte 5)
Start Delimiter
0x7E
MSB
Remote Command Response
ZigBee Transmit Request
Length
API Identifier Value: 0x97
If a module receives a remote command response RF data frame in response to a Remote AT
Command Request, the module will send a Remote AT Command Response message out the
UART. Some commands may send back multiple frames--for example, Node Discover (ND)
command.
Figure 6‐12. Remote AT Command Response.
API Identifier Value: 0x10
A TX Request message will cause the module to send RF Data as an RF Packet.TX Packet Frames
© 2008 Digi International, Inc.
LSB
API Identifier
0x97
API-specific Structure
Address (bytes 6-13)
64-bit Responder
Indicates the 64-bit address
of the remote module that is
responding to the Remote
AT Command request
Frame Data
Identifier-specific Data
cmdData
Checksum
1 Byte
16-bit Responder Network Address (bytes
Set to the 16-bit network
address of the remote.
Set to 0xFFFE if
unknown.
14-15)
Name of the command. Two
ASCII characters that
identify the AT command
Command Name (bytes
16-17)
0 = OK
1 = Error
2 = Invalid Command
3 = Invalid Parameter
Status (byte 18)
Command Data (byte 19-n)
The value of the requested
register.
     62