Specifications of XB24-BUIT-004

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
2 mW (3 dBm)
Sensitivity
-96dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
38mA
Current - Transmitting
35mA
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee ZNet 2.5/XBee‐PRO ZNet 2.5 ZigBee OEM RF Modules v1.x4x 
Start Delimiter
* Length [Bytes] = API Identifier + Frame ID + AT Command + Parameter Value
** “M” value was arbitrarily selected.
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no response is sent.
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no response is sent.
Byte 1
0x7E
Start Delimiter
AT Command
* Length [Bytes] = API Identifier + Frame ID + AT Command
** “R” value was arbitrarily selected.
AT Command - Queue Parameter Value
Byte 1
0x7E
Start Delimiter
Start Delimiter
API Identifier Value: 0x08
Allows for module parameter registers to be queried or set.
Figure 6‐5.
Figure 6‐6.
Figure 6‐7.
A string parameter used with the NI (Node Identifier), ND (Node Discover) and DH (Destination
Address High) command is terminated with a 0x00 character.
API Identifier Value: 0x09
This API type allows module parameters to be queried or set. In contrast to the “AT Command”
API type, new parameter values are queued and not applied until either the “AT Command” (0x08)
API type or the AC (Apply Changes) command is issued. Register queries (reading parameter
values) are returned immediately.
Figure 6‐8.
© 2008 Digi International, Inc.
0x7E
0x7E
0x00
Frame ID (Byte 5)
Frame ID (Byte 5)
Bytes 2-3
Length*
0x05
0x00
MSB
MSB
Bytes 2-3
AT Command Frames
Example: API frames when reading the NJ parameter value of the module.
Example: API frames when modifying the NJ parameter value of the module.
AT Command Frames 
(Note that frames are identical to the “AT Command” API type except for the API identifier.)
Length*
Length
Length
API Identifier
0x04
LSB
LSB
Byte 4
API Identifier
API Identifier
0x08
0x08
0x09
API Identifier
API-specific Structure
API-specific Structure
Byte 4
0x08
Frame Data
Frame Data
Frame ID**
0x4D (M)
Byte 5
Identifier-specific Data
Command Name - Two
ASCII characters that
identify the AT Command.
Identifier-specific Data
Command Name - Two
ASCII characters that
identify the AT Command.
AT Command (Bytes 6-7)
AT Command (Bytes 6-7)
cmdData
cmdData
Frame ID**
0x52 (R)
Byte 5
0x4E (N) 0x4A (J)
Checksum
Checksum
1 Byte
1 Byte
AT Command
Bytes 6-7
0x4E (N) 0x4A (J)
AT Command
If present, indicates the requested parameter
value to set the given register.
If no characters present, register is queried.
If present, indicates the requested parameter
value to set the given register.
If no characters present, register is queried.
Bytes 6-7
Parameter Value (Byte(s) 8-n)
Parameter Value (Byte(s) 8-n)
Parameter Value
Bytes 8
0x40
Checksum
Byte 8
0x0D
Checksum
Byte 9
0xD2
     59