XBP09-XCUIT-009 Digi International, XBP09-XCUIT-009 Datasheet - Page 22

no-image

XBP09-XCUIT-009

Manufacturer Part Number
XBP09-XCUIT-009
Description
XBEE-PRO XSC -100MW 9.6KBPS
Manufacturer
Digi International
Series
XBEE-PRO™r

Specifications of XBP09-XCUIT-009

Frequency
910MHz ~ 918MHz
Data Rate - Maximum
9.6kbps
Modulation Or Protocol
FHSS
Power - Output
20dBm (100mW)
Sensitivity
-106dBm
Voltage - Supply
3 V ~ 3.6 V
Current - Receiving
65mA
Current - Transmitting
265mA
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1132
Q4197953
XBP09-XCUIT-009
XBee‐PRO® XSC OEM RF Modules  
Command Summary
AT Command: ATBT
Binary Command: 0x04 (4 decimal)
Parameter Range:2 – 0xFFFF
Default Parameter Value: 0x0A (10
decimal)
Number of bytes returned: 2
Related Commands: AT (Guard Time
After), CC (Command Sequence
Character)
Command Summary
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 – 0x7F
Default Parameter Value: 0x2B (ASCII “+”
sign)
Number of bytes returned: 1
Related Commands: AT (Guard Time
After), BT (Guard Time Before)
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 – 3
Default Parameter Value: 0
Number of bytes returned: 1
Parameter
[x 100 milliseconds]
Value
0
1
2
3
4
addressed to module is sent
Assert only when packet
BT (Guard Time Before) Command
CC (Command Sequence Character) Command
CD (DO3 Configuration) Command
Table 3‐02. Parameter Sent vs. Parameter Stored
Configuration
© 2010 Digi International, Inc.
Default high
Default low
(reserved)
RX LED
BD Parameter Sent (HEX)
E100
12C
0
4
6
Description
Description
<Command Mode Options> BT
Command is used to set the DI pin
silence time that must precede the
command sequence character (CC
Command) of the AT Command Mode
Sequence. Refer to the AT Commands
section [p] to view the default AT
Command Mode Sequence.
<Command Mode Options> CC
Command is used to set the ASCII
character to be used between Guard
Times of the AT Command Mode
Sequence (BT+ CC + AT). The AT
Command Mode Sequence activates AT
Command Mode (from Idle Mode).
Refer to the AT Commands section [p] to
view the default AT Command Mode
Sequence.
Description
<Command Mode
Options> CD
Command is used to
define the behavior of
the DO3/RX LED line.
Interface Data Rate (bps)
19,200
57600
57600
1200
300
BD Parameter Stored (HEX)
E883
12B
0
4
6
     22

Related parts for XBP09-XCUIT-009