XB24-BPDK Digi International/Maxstream, XB24-BPDK Datasheet - Page 71

no-image

XB24-BPDK

Manufacturer Part Number
XB24-BPDK
Description
KIT DEVELOPMENT XBEE SERIES 2
Manufacturer
Digi International/Maxstream
Series
XBee™r
Type
802.15.4/Zigbeer
Datasheet

Specifications of XB24-BPDK

Frequency
2.4GHz
For Use With/related Products
XBee™ Series 2 Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Special
Node types that support the command: C = Coordinator, R = Router, E = End Device
Addressing
7.  XBee ZNet 2.5 Command Reference Tables
Table 7‐02. Addressing Commands)
Table 7‐01. Special Commands
AT
Command
DH
DL
MY
MP
NC
SH
SL
NI
DD
ZA
SE
AT
Command
WR
WB
RE
FR
NR
2
2
2
2
Name and Description
Destination Address High. Set/Get the upper 32 bits of the 64-bit destination address.
When combined with DL, it defines the destination address used for transmission.
0x000000000000FFFF is the broadcast address for the PAN. DH is not supported in
API Mode. 0x0000000000000000 is the Coordinator’s 16-bit network address.
Destination Address Low. Set/Get the lower 32 bits of the 64-bit destination address.
When combined with DH, DL defines the destination address used for transmission.
0x000000000000FFFF is the broadcast address for the PAN. DL is not supported in API
Mode. 0x0000000000000000 is the Coordinator’s 16-bit network address.
16-bit Network Address. Get the 16-bit network address of the module.
16-bit Parent Network Address. Get the 16-bit parent network address of the module. E
Number of Children. Read the number of end device children that have joined to the
device. This command returns the number of child table entries currently in use.
Serial Number High. Read high 32 bits of the RF module's unique IEEE 64-bit
address. 64-bit source address is always enabled.
Serial Number Low. Read low 32 bits of the RF module's unique IEEE 64-bit address.
64-bit source address is always enabled.
Node Identifier. Stores a string identifier. The register only accepts printable ASCII
data. In AT Command Mode, a string can not start with a space. A carriage return ends
the command. Command will automatically end when maximum bytes for the string
have been entered. This string is returned as part of the ND (Node Discover) command.
This identifier is also used with the DN (Destination Node) command.
Device Type Identifier. Stores a device type value. This value can be used to
differentiate multiple XBee-based products.
ZigBee Application Layer Addressing. Set/read the Zigbee application layer
addressing enabled attribute. If enabled, data packets will use the SE, DE, and CI
commands to address Zigbee application layer source and destination endpoints, and
the cluster ID fields in all data transmissions. ZA is only supported in the AT firmware.
Source Endpoint. Set/read the ZigBee application layer source endpoint value. If
ZigBee application layer addressing is enabled (ZA command), this value will be used
as the source endpoint for all data transmissions. SE is only supported in AT
firmware.The default value 0xE8 (Data endpoint) is the Digi data endpoint
Name and Description
Write. Write parameter values to non-volatile memory so that parameter modifications
persist through subsequent resets.
Note: Once WR is issued, no additional characters should be sent to the module until
after the "OK\r" response is received. The WR command should be used sparingly. The
EM250 supports a limited number of write cycles.“
Write Binding Table: Writes the current binding table to non-volative memory.
Restore Defaults. Restore module parameters to factory defaults. RE command does
not reset the ID parameter.
Software Reset. Reset module. Responds immediately with an “OK” then performs a
reset ~2 seconds later. Use of the FR command will cause a network layer restart on the
node if SC or ID were modified since the last reset.
Network Reset. Reset network layer parameters on one or more modules within a PAN.
Responds immediately with an “OK” then causes a network restart. All network
configuration and routing information is consequently lost.
If NR = 0: Resets network layer parameters on the node issuing the command.
If NR = 1: Sends broadcast transmission to reset network layer parameters on all nodes
in the PAN.
© 2008 Digi International, Inc.
Node
Type
CRE
CRE
CRE
CR
CRE
CRE
CRE
CRE
CRE
CRE
Node Type
CRE
CRE
CRE
CRE
CRE
1
Parameter Range
0 - 0xFFFFFFFF
0 - 0xFFFFFFFF
0 - 0xFFFE
[read-only]
0 - 0xFFFE
[read-only]
0 - 8
0 - 0xFFFFFFFF
[read-only]
0 - 0xFFFFFFFF
[read-only]
20-Byte printable
ASCII string
0 - 0xFFFFFFFF [read-
only]
0 - 1
1 - 0xEF
1
--
Parameter Range Default
--
--
--
0 - 1
Default
0
0xFFFF(Coordinator)
0 (Router/End Device)
0xFFFE
0xFFFE
read-only
factory-set
factory-set
ASCII space
character (0x20)
0x20000
0
0xE8
--
--
--
--
--
     70

Related parts for XB24-BPDK