DVK-BTM411 Laird Technologies, DVK-BTM411 Datasheet - Page 44

BLUETOOTH EVAL BOARD BTM411

DVK-BTM411

Manufacturer Part Number
DVK-BTM411
Description
BLUETOOTH EVAL BOARD BTM411
Manufacturer
Laird Technologies
Type
Transceiverr
Datasheets

Specifications of DVK-BTM411

Frequency
2.4GHz
Wireless Frequency
2.402 GHz to 2.48 GHz
Interface Type
UART
Data Rate
2.1 Mbps
Operating Voltage
3 V to 3.3 V
Antenna
Multilayer Ceramic Integrated
Operating Temperature Range
- 30 C to + 70 C
Output Power
4 dBm
Technology/ Type
Development Kit
For Use With/related Products
BTM411
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
DVK-BTM411

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DVK-BTM411-02
Manufacturer:
LAIRD
Quantity:
2
BTM410/411
Bluetooth
AT COMMAND SET
REFERENCE
44 www.lairdtech.com
®
AT Data Module
Register
S334
S504
S505
S506
S507
S508
S509
S510
S511
Deflt.
0
0
10
0
0
640
160
640
160
Range
0..1
0..1
2..120
0..1
0..2
11..2550
11..2550
11..2550
11..2550
Description
Enable Extended Sdp Error Codes
0 - disable
1 – enable
Enable silent operation:
Setting to 1 will force S0 to -1 and will suppress messages arising
from connections or pairing. E.g. CONNECT, NO CARRIER, RING,
PAIR etc.
Suppressing connection based messaged allows the device to be
configured in cable replacement mode
Minimum delay before abandoning connection attempt as a
master.
Referenced by ATD. In units of seconds. See S Registers 530 and
543 also. Please note that as disconnection time can vary, this
register only guarantees the minimum delay. Note that for invalid
addresses specified in the ATD command, the “NO CARRIER”
response will be immediate. See S register 560 for specifying dis-
connect max timeout
Enable/Disable echoes. The ATEn command also affects this.
When set to 0, a connection can be dropped using ^^^ escape
sequence only and the state of DSR line is ignored.
When set to 1 a connection can be dropped using EITHER the ^^^
escape sequence OR the DSR handshaking line. When set to 2, a
connection can only dropped using a deassertion of DSR. Mode 2
provides for the highest data transfer rate.
If the status of the DSR line is to be conveyed to the remote device
as a low bandwidth signal then this register MUST be set to 0,
otherwise a deassertion of DSR will be seen as a request to drop
the Bluetooth® connection. This register affects S Register 536 –
see details of 536
Page Scan Interval in milliseconds. Minimum is 11.25ms so
10/11ms will give 11.25ms, refer to Section 6, pg. 40.
Page Scan Window in milliseconds. Minimum is 11.25ms so
10/11ms will give 11.25ms, refer to Section 6, pg. 40.
Inquiry Scan Interval in milliseconds. Minimum is 11.25ms so
10/11ms will give 11.25ms, refer to Section 6, pg. 40.
Inquiry Scan Window in milliseconds. Minimum is 11.25ms so
10/11ms will give 11.25ms, refer to Section 6, pg. 40.
Laird Technologies

Related parts for DVK-BTM411