DVK-BTM411 Laird Technologies, DVK-BTM411 Datasheet - Page 25

BLUETOOTH EVAL BOARD BTM411

DVK-BTM411

Manufacturer Part Number
DVK-BTM411
Description
BLUETOOTH EVAL BOARD BTM411
Manufacturer
Laird Technologies
Type
Transceiverr
Datasheets

Specifications of DVK-BTM411

Frequency
2.4GHz
Wireless Frequency
2.402 GHz to 2.48 GHz
Interface Type
UART
Data Rate
2.1 Mbps
Operating Voltage
3 V to 3.3 V
Antenna
Multilayer Ceramic Integrated
Operating Temperature Range
- 30 C to + 70 C
Output Power
4 dBm
Technology/ Type
Development Kit
For Use With/related Products
BTM411
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
DVK-BTM411

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DVK-BTM411-02
Manufacturer:
LAIRD
Quantity:
2
BTM410/411
Bluetooth
AT COMMAND SET
REFERENCE
25 www.lairdtech.com
®
AT Data Module
1. ATX”<string>”
2. ATY”<string>”
3. ^^^ {Enter Local Command Mode}
4. !!! {Enter Remote Command Mode}
This command is used to send data to the remote device when in local command and connected mode.
The parameter <string> is any string not more than 29 characters long whereby a non printable
character (\hh, see below) counts 3 characters. This restriction results from the maximum AT command
length which is 34 (query by ATI15). The difference of 5 is caused by “ATX” (3 characters) and the
enclosing quotation marks (2 characters).
If the maximum string length is exceeded, ERROR 05 (syntax error) will occur.
If a non-visual character is to be sent then insert the escape sequence \hh where hh are two
hexadecimal digits. The 3 character sequence \hh will be converted into a single byte before
transmission to the peer.
Response: <cr,lf>OK<cr,lf>
Or
<cr,lf>ERROR 05<cr,lf>
This command is similar to ATX in syntax and functionality, except that the string is only copied to
the output rf buffer. Only when an empty string is presented, all pending data in the output rf buffer
will be flushed out.
The parameter <string> is any string not more than 29 characters long whereby a non printable
character (\hh, see below) counts 3 characters. This restriction results from the maximum AT command
length which is 34 (query by ATI15). The difference of 5 is caused by “ATX” (3 characters) and the
enclosing quotation marks (2 characters).
If the maximum string length is exceeded, ERROR 05 (syntax error) will occur.
If a non-visual character is to be sent then insert the escape sequence \hh where hh are two
hexadecimal digits. The 3 character sequence \hh will be converted into a single byte before
transmission to the peer.
Response: <cr,lf>OK<cr,lf>
Or
<cr,lf>ERROR 05<cr,lf>
When in data and connected mode and when S 507 is set to 0 or 1, the host can force the device into
a command and connected mode so that AT Commands can be issued to the device. The character in
this escape sequence is specified in the S2 register, so it can be changed. In addition, the escape sequence
guard time is specified by S Register 12. By default the guard time is set to 100 milliseconds.
Leaving data mode by “^^^” has a severe penalty on data throughput, because each incoming
character needs to be checked for ‘^’ with respect to the guard time.
Alternatively, a de-assertion of the DTR/DSR line can be used as the only trigger to leave data mode
(S507=2). This gives a significant higher data throughput because data is passed directly between UART
and RF without character checking. Please refer to Section 6, pg. 26 for more information.
In modems this escape sequence is usually “+++”. “^^^” is specified to avoid confusion when the
module is providing access to a modem.
Response: <cr,lf>OK<cr,lf>
When in data and connected mode, the host can force the remote device into a command and
connected mode so that AT Commands can be issued to the device remotely. The escape sequence
guard time is specified by S Register 12 and is the same as per the ^^^ escape sequence. By default
the guard time is set to 100 milliseconds. The remote device issues ATO as normal to return to data
mode (Refer to 5). For this command to be effective S Register 536 must be set to 1.
Response: <cr,lf>OK<cr,lf>
{Send Data in Local Command and Connected Mode}
{Send Data in Local Command and Connected Mode}
(e.g. <string> too long)
(e.g. <string> too long)
Laird Technologies

Related parts for DVK-BTM411