3.8 Selecting Wide Band or Narrow Band Measurement
The GUI provides for two measurement algorithm options. The Wide Band measurement method is
optimal for measuring power from equipment with switching power supplies. The Narrow Band method
works well with conventional loads. All measurement displays, dials and graph are updated with the
appropriate data based on the Wide Band / Narrow Band selection.
3.9 Selecting the Sample Interval
Sample Interval provides a menu of sample sizes for display averaging. The 1 Second setting updates
the display with every sample once a second. The 5 Seconds setting averages 5 samples and updates
the display every 5 seconds, etc. Interval Cnt provides an index for the next display update. For
example, if Sample Interval is set to 5 Seconds, Interval Cnt will count from 1 to 5.
3.10
The Alarm Status indicator turns red if any Alarm Status Threshold is exceeded. See
more information.
Rev. 1.2
Alarm Status
78M6612 OMU1-S-RF Demo Unit User Manual
Wide Band or
Narrow Band
Section 4.16
Sample Interval
Interval Cnt
for
25