2320018 Phoenix Contact, 2320018 Datasheet - Page 4

CONVERTER DC-DC 12-24/5-15VDC 2A

2320018

Manufacturer Part Number
2320018
Description
CONVERTER DC-DC 12-24/5-15VDC 2A
Manufacturer
Phoenix Contact
Series
Minir
Type
Isolatedr
Datasheet

Specifications of 2320018

Output
12V
Number Of Outputs
1
Power (watts)
24W
Mounting Type
DIN Rail
Voltage - Input
12 ~ 24V
Package / Case
Module
1st Output
12 VDC @ 2A
Size / Dimension
4.21" L x 0.89" W x 3.90" H (107mm x 22.5mm x 99mm)
Operating Temperature
-25°C ~ 70°C
Power (watts) - Rated
24W
Efficiency
88%
Approvals
cUL, EN, UL, VDE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
104346_en_00
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Max. permissible relative humidity (operation)
Vibration (operation)
Shock
Pollution degree in acc. with EN 50178
Climatic class
Approvals
UL approvals
Conformance with EMC guideline 2004/108/EC and for low-voltage guideline 2006/95/EC
Noise immunity according to EN 61000-6-2
Electrostatic discharge
Electromagnetic HF field
Fast transients (burst)
Surge current loads (surge)
Conducted interference
Voltage dips
Emitted interference in acc. with EN 61000-6-3
Radio interference voltage in acc. with EN 55011
Emitted radio interference in acc. with EN 55011
Current approvals can be found for the product in the download area.
EN 61000-4-2
Housing
Contact discharge
Discharge in air
Comments
EN 61000-4-3
Housing
Frequency range
Field intensity
Comments
EN 61000-4-4
Input
Output
Signal
Comments
EN 61000-4-5
Input
EN 61000-4-6
Input/output
Frequency range
EN 61000-4-11
Input
Comments
8 kV (Contact discharge)
Criterion B
10 V/m
2 kV (level 3 - asymmetrical: conductor to ground)
Criterion B
2 kV (Level 3)
Level 3
Criterion B
-25 °C ... 70 °C (> +60°C derating)
-40 °C ... 85 °C
≤ 95 % (At +25°C, no condensation)
< 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6
15 Hz ...150 Hz, 2.3 g
30g in all directions in acc. with IEC 60068-2-27
2
3K3 (in acc. with EN 60721)
UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950
> Level 3
8 kV (Air discharge)
Level 3
80 MHz ... 3 GHz
Criterion A
4 kV (level 4 - asymmetrical: conductor to ground)
1 kV (Level 2 - asymmetrical cable to ground)
1 kV (Level 3)
0.15 MHz ... 80 MHz (10 V)
(> 10 ms)
EN 55011 (EN 55022) Class B, area of application: Industry and residential
EN 55011 (EN 55022) Class B, area of application: Industry and residential
MINI-PS- 12- 24DC/ 5-15DC/2
PHOENIX CONTACT
4

Related parts for 2320018