2320018 Phoenix Contact, 2320018 Datasheet

CONVERTER DC-DC 12-24/5-15VDC 2A

2320018

Manufacturer Part Number
2320018
Description
CONVERTER DC-DC 12-24/5-15VDC 2A
Manufacturer
Phoenix Contact
Series
Minir
Type
Isolatedr
Datasheet

Specifications of 2320018

Output
12V
Number Of Outputs
1
Power (watts)
24W
Mounting Type
DIN Rail
Voltage - Input
12 ~ 24V
Package / Case
Module
1st Output
12 VDC @ 2A
Size / Dimension
4.21" L x 0.89" W x 3.90" H (107mm x 22.5mm x 99mm)
Operating Temperature
-25°C ~ 70°C
Power (watts) - Rated
24W
Efficiency
88%
Approvals
cUL, EN, UL, VDE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MINI-PS- 12- 24DC/ 5-15DC/2
Power supply unit
INTERFACE
Data sheet
104346_en_00
1
The DC/DC converter converts the DC voltage of 12 V DC ...
24 V DC to an adjustable, controlled and electrically isolated
5 V DC ... 15 V DC output voltage.
Due to electrical isolation, the DC voltage circuits are
electrically isolated from each other in a safe way. The active
"DC-OK" switching output as well as an LED are available for
signaling. With a design width of only 22.5 mm, the housing is
extremely slim.
Description
DANGER OF EXPLOSION!
Only remove equipment when it is disconnected and not in the potentially explosive area.
DANGER
Components with dangerously high voltage and high stored energy are located in the device!
Never carry out work on live parts!
Depending on the ambient temperature and the load, the housing can become very hot!
Make sure you always use the latest documentation.
It can be downloaded from the product at www.phoenixcontact.net/catalog.
© PHOENIX CONTACT 2010-04-26
Features
Reliable power supply unit even at high ambient
temperatures
Reliable starting of heavy loads using the U/I
characteristic curve
Can be used worldwide in all industrial sectors due to a
wide-range input and an international approval package
High operating safety due to long mains buffering under
full load and high MTBF (> 500,000 h)

Related parts for 2320018

2320018 Summary of contents

Page 1

... Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. © PHOENIX CONTACT 2010-04-26 Features – Reliable power supply unit even at high ambient temperatures – ...

Page 2

... Block diagram ............................................................................................................................. 7 Safety notes ................................................................................................................................ 8 Installation ................................................................................................................................... 9 Installation position...................................................................................................................... Assembly ...................................................................................................................................................................8 Removing...................................................................................................................................................................8 10 Input ............................................................................................................................................ Protection of the primary side.....................................................................................................................................8 11 Output ......................................................................................................................................... Protection of the secondary side ................................................................................................................................9 12 Signaling ..................................................................................................................................... Active signal output ..................................................................................................................................................10 13 Function .................................................................................................................................... Thermal behavior .....................................................................................................................................................10 Parallel operation .....................................................................................................................................................10 Redundant operation ...............................................................................................................................................11 Increased performance ............................................................................................................................................11 104346_en_00 MINI-PS- 12- 24DC/ 5-15DC/2 10 PHOENIX CONTACT ...

Page 3

... Insulation voltage input/output Degree of protection Class of protection MTBF Type of housing Housing material Dimensions (state of delivery) Weight 104346_en_00 MINI-PS- 12- 24DC/ 5-15DC/2 Type Order No. MINI-PS- 12- 24DC/ 5-15DC/2 2320018 ... ... (> 10 start Approx. 2.3 A (12 V DC) Approx. 1.1 A (24 V DC) < (typical > (12 V DC) > (24 V DC) < 0.5 s 6.3 A (slow-blow, internal ± ...

Page 4

... EN 61000-4-5 Input 2 kV (Level (Level 3) EN 61000-4-6 Input/output Level 3 Frequency range 0.15 MHz ... 80 MHz ( 61000-4-11 Input (> 10 ms) Comments Criterion B EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential MINI-PS- 12- 24DC/ 5-15DC/2 PHOENIX CONTACT 4 ...

Page 5

... Universal DIN rail adapter UTA 107/30 6 solid Input 0.2 - 2.5 0.2 - 2.5 Output 0.2 - 2.5 0.2 - 2.5 Signal 0.2 - 2.5 0 ... ... (> 10 start 6.3 A (slow-blow, internal) Pluggable screw connection ± ... (-25 °C ... 60 °C) Pluggable screw connection [mm ] AWG [Nm] stranded Torque 0 0 0.5 - 0.6 5 PHOENIX CONTACT ...

Page 6

... All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection must be guaranteed. ATTENTION: Danger if used improperly The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations must be observed. 104346_en_00 DC OK MINI-PS- 12- 24DC/ 5-15DC/2 PHOENIX CONTACT 6 ...

Page 7

... Mounting position: Installation depth 107 mm (+ DIN rail) 104346_en_00 113,5 107 MINI-PS- 12- 24DC/ 5-15DC/2 ATTENTION: Module can become damaged To ensure sufficient convection, we recommend the following minimum spacing be used between modules above and below The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. PHOENIX CONTACT 7 ...

Page 8

... The device must be installed in acc. with the regulations 60950. An internal fuse is provided for device protection. Additional device protection is not required. MINI-PS- 12- 24DC/ 5-15DC/2 ATTENTION: Module can become damaged If an internal fuse is triggered, there is a device malfunction. In this case, the device must be inspected in the factory. PHOENIX CONTACT 8 ...

Page 9

... The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. State 2 OFF (in reference to "–") ≤ 0 OUT Secondary load short-circuit or overload No mains voltage or device defective PHOENIX CONTACT 9 ...

Page 10

... DC fuse or circuit breaker). This prevents high return currents in the event of a secondary device fault. MINI-PS- 12- 24DC/ 5-15DC/2 > 0 between the "DC OK" and "-" OUT N PHOENIX CONTACT 10 ...

Page 11

... PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 104346_en_00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 Redundant operation I N Redundant circuits are suitable for supplying systems, which − ...