71M6511H-IGT/F Maxim Integrated Products, 71M6511H-IGT/F Datasheet - Page 23

IC ENERGY METER RESIDENT 64-LQFP

71M6511H-IGT/F

Manufacturer Part Number
71M6511H-IGT/F
Description
IC ENERGY METER RESIDENT 64-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 71M6511H-IGT/F

Processor Series
6511x
Core
80515
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
64 KB
Data Ram Size
7 KB
Interface Type
I2C, SSI, UART
Maximum Clock Frequency
5 MHz
Number Of Programmable I/os
12
Number Of Timers
2
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
LQFP-64
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
71M6511H-DB
Minimum Operating Temperature
- 40 C
On-chip Adc
22 bit Delta Sigma
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6511H-IGT/F
Manufacturer:
PERICOM
Quantity:
1 200
Part Number:
71M6511H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Serial Interface 1 Control Register (S1CON).
The function of the serial port depends on the setting of the Serial Port Control Register S1CON.
Note: The speed in Mode 2 depends on the SMOD bit in the SFR PCON. See the PCON register description.
Page: 23 of 98
S0CON.7
S0CON.6
S0CON.5
S0CON.4
S0CON.3
S0CON.2
S0CON.1
S0CON.0
Bit
A Maxim Integrated Products Brand
MSB
Symbol
SM
REN0
SM20
TB80
RB80
SM0
SM1
TI0
RI0
-
These two bits set the UART0 mode:
Enables the inter-processor communication feature.
If set, enables serial reception. Cleared by software to disable reception.
The 9
MPU, depending on the function it performs (parity check, multiprocessor
communication etc.)
In Modes 2 and 3 it is the 9
RB80 is the stop bit. In Mode 0 this bit is not used. Must be cleared by
software
Transmit interrupt flag, set by hardware after completion of a serial
transfer. Must be cleared by software.
Receive interrupt flag, set by hardware after completion of a serial
reception. Must be cleared by software
Function
Mode
th
SM21
0
1
2
3
transmitted data bit in Modes 2 and 3. Set or cleared by the
© 2005–2010 Teridian Semiconductor Corporation
Table 17: The S0CON Bit Functions
REN1
Description
Table 16: The S1CON register
8-bit UART
9-bit UART
9-bit UART
N/A
th
TB81
data bit received. In Mode 1, if SM20 is 0,
Single-Phase Energy Meter IC
SM0
RB81
0
0
1
1
71M6511/71M6511H
TI1
SM1
DATA SHEET
0
1
0
1
RI1
LSB
NOVEMBER 2010
V2.7

Related parts for 71M6511H-IGT/F