SAF-XE167F-48F66L AC Infineon Technologies, SAF-XE167F-48F66L AC Datasheet - Page 59

IC MCU 16BIT FLASH PG-LQFP-144

SAF-XE167F-48F66L AC

Manufacturer Part Number
SAF-XE167F-48F66L AC
Description
IC MCU 16BIT FLASH PG-LQFP-144
Manufacturer
Infineon Technologies
Series
XE16xr
Datasheet

Specifications of SAF-XE167F-48F66L AC

Core Processor
C166SV2
Core Size
16-Bit
Speed
66MHz
Connectivity
CAN, EBI/EMI, I²C, LIN, SPI, SSC, UART/USART, USI
Peripherals
I²S, POR, PWM, WDT
Number Of I /o
118
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
34K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 24x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LFQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
FXE167F48F66LACXP
SAF-XE167F-48F66LACIN
SP000363821
SP000363822
XE167x
XE166 Family Derivatives
Functional Description
With its maximum resolution of 2 system clock cycles, the GPT2 module provides
precise event control and time measurement. It includes two timers (T5, T6) and a
capture/reload register (CAPREL). Both timers can be clocked with an input clock which
is derived from the CPU clock via a programmable prescaler or with external signals. The
counting direction (up/down) for each timer can be programmed by software or altered
dynamically with an external signal on a port pin (TxEUD). Concatenation of the timers
is supported with the output toggle latch (T6OTL) of timer T6, which changes its state on
each timer overflow/underflow.
The state of this latch may be used to clock timer T5, and/or it may be output on pin
T6OUT. The overflows/underflows of timer T6 can also be used to clock the CAPCOM2
timers and to initiate a reload from the CAPREL register.
The CAPREL register can capture the contents of timer T5 based on an external signal
transition on the corresponding port pin (CAPIN); timer T5 may optionally be cleared
after the capture procedure. This allows the XE167 to measure absolute time differences
or to perform pulse multiplication without software overhead.
The capture trigger (timer T5 to CAPREL) can also be generated upon transitions of
GPT1 timer T3 inputs T3IN and/or T3EUD. This is especially advantageous when T3
operates in Incremental Interface Mode.
Data Sheet
57
V2.1, 2008-08

Related parts for SAF-XE167F-48F66L AC