PIC18F24J11-I/SO Microchip Technology, PIC18F24J11-I/SO Datasheet - Page 383

IC PIC MCU FLASH 16K 2V 28-SOIC

PIC18F24J11-I/SO

Manufacturer Part Number
PIC18F24J11-I/SO
Description
IC PIC MCU FLASH 16K 2V 28-SOIC
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr

Specifications of PIC18F24J11-I/SO

Program Memory Type
FLASH
Program Memory Size
16KB (8K x 16)
Package / Case
28-SOIC (7.5mm Width)
Core Processor
PIC
Core Size
8-Bit
Speed
48MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
16
Ram Size
3.8K x 8
Voltage - Supply (vcc/vdd)
2.15 V ~ 3.6 V
Data Converters
A/D 10x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
PIC18F
Core
PIC
Data Bus Width
8 bit
Data Ram Size
3776 B
Interface Type
EUSART, I2C, SPI
Maximum Clock Frequency
48 MHz
Number Of Timers
5
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, DM183032, DM183022, DM183033, DV164136
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 10 Channel
Package
28SOIC W
Device Core
PIC
Family Name
PIC18
Maximum Speed
48 MHz
Operating Supply Voltage
2.5|3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
XLT28SO-1 - SOCKET TRANSITION 28SOIC 300MILAC164332 - MODULE SKT FOR 28SOIC 18F45J10
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F24J11-I/SO
Manufacturer:
Microchip Technology
Quantity:
1 960
24.5
Time can be precisely measured after the ratio (C/I) is
measured from the current and capacitance calibration
step by following these steps:
1.
2.
3.
4.
5.
FIGURE 24-3:
© 2009 Microchip Technology Inc.
Initialize the A/D Converter and the CTMU.
Set EDG1STAT.
Set EDG2STAT.
Perform an A/D conversion.
Calculate the time between edges as T = (C/I) * V,
where I is calculated in the current calibration step
(Section 24.3.1 “Current Source Calibration”),
C is calculated in the capacitance calibration step
(Section 24.3.2 “Capacitance Calibration”) and
V is measured by performing the A/D conversion.
Measuring Time with the CTMU
Module
TYPICAL CONNECTIONS AND INTERNAL CONFIGURATION FOR TIME
MEASUREMENT
CTEDG1
CTEDG2
AN
R
PR
X
EDG2
PIC18F46J11 Device
EDG1
C
AD
A/D Converter
Current Source
CTMU
PIC18F46J11 FAMILY
Output Pulse
It is assumed that the time measured is small enough
that the capacitance, C
to the A/D Converter. For the smallest time measure-
ment, always set the A/D Channel Select register
(AD1CHS) to an unused A/D channel; the correspond-
ing pin for which is not connected to any circuit board
trace. This minimizes added stray capacitance, keep-
ing the total circuit capacitance close to that of the A/D
Converter itself (4-5 pF). To measure longer time
intervals, an external capacitor may be connected to an
A/D channel and this channel selected when making a
time measurement.
OFFSET
, provides a valid voltage
DS39932C-page 383

Related parts for PIC18F24J11-I/SO