PIC16F616-I/SL Microchip Technology, PIC16F616-I/SL Datasheet - Page 46

IC PIC MCU FLASH 2KX14 14SOIC

PIC16F616-I/SL

Manufacturer Part Number
PIC16F616-I/SL
Description
IC PIC MCU FLASH 2KX14 14SOIC
Manufacturer
Microchip Technology
Series
PIC® 16Fr

Specifications of PIC16F616-I/SL

Program Memory Type
FLASH
Program Memory Size
3.5KB (2K x 14)
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Core Processor
PIC
Core Size
8-Bit
Speed
20MHz
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
11
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
PIC16F
Core
PIC
Data Bus Width
8 bit
Data Ram Size
128 B
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
11
Number Of Timers
3
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP1631RD-DCPC1 - REF DES BATT CHARG OR LED DRIVERAC162083 - HEADER MPLAB ICD2 PIC16F616 8/14
Eeprom Size
-
Connectivity
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC16F616-I/SL
Manufacturer:
MICROCHIP
Quantity:
400
Part Number:
PIC16F616-I/SL
Manufacturer:
Microchip Technology
Quantity:
45 197
Part Number:
PIC16F616-I/SL
Manufacturer:
MICROCHIP
Quantity:
20 000
Part Number:
PIC16F616-I/SL
0
Company:
Part Number:
PIC16F616-I/SL
Quantity:
4 790
Company:
Part Number:
PIC16F616-I/SL
Quantity:
4 626
PIC16F610/616/16HV610/616
5.1.3
A single software programmable prescaler is available
for use with either Timer0 or the Watchdog Timer
(WDT), but not both simultaneously. The prescaler
assignment is controlled by the PSA bit of the OPTION
register. To assign the prescaler to Timer0, the PSA bit
must be cleared to a ‘0’.
There are 8 prescaler options for the Timer0 module
ranging from 1:2 to 1:256. The prescale values are
selectable via the PS<2:0> bits of the OPTION register.
In order to have a 1:1 prescaler value for the Timer0
module, the prescaler must be assigned to the WDT
module.
The prescaler is not readable or writable. When
assigned to the Timer0 module, all instructions writing to
the TMR0 register will clear the prescaler.
When the prescaler is assigned to WDT, a CLRWDT
instruction will clear the prescaler along with the WDT.
5.1.3.1
As a result of having the prescaler assigned to either
Timer0 or the WDT, it is possible to generate an
unintended device Reset when switching prescaler
values. When changing the prescaler assignment from
Timer0 to the WDT module, the instruction sequence
shown in Example 5-1 must be executed.
EXAMPLE 5-1:
DS41288C-page 44
BANKSEL
CLRWDT
CLRF
BANKSEL
BSF
CLRWDT
MOVLW
ANDWF
IORLW
MOVWF
b’11111000’
OPTION_REG,W
b’00000101’
OPTION_REG
SOFTWARE PROGRAMMABLE
PRESCALER
TMR0
TMR0
OPTION_REG
OPTION_REG,PSA ;Select WDT
Switching Prescaler Between
Timer0 and WDT Modules
;
;
CHANGING PRESCALER
(TIMER0 → WDT)
;
;Clear WDT
;Clear TMR0 and
;prescaler
;
;Mask prescaler
;bits
;Set WDT prescaler
;to 1:32
Preliminary
When changing the prescaler assignment from the
WDT to the Timer0 module, the following instruction
sequence must be executed (see Example 5-2).
EXAMPLE 5-2:
5.1.4
Timer0 will generate an interrupt when the TMR0
register overflows from FFh to 00h. The T0IF interrupt
flag bit of the INTCON register is set every time the
TMR0 register overflows, regardless of whether or not
the Timer0 interrupt is enabled. The T0IF bit must be
cleared in software. The Timer0 interrupt enable is the
T0IE bit of the INTCON register.
5.1.5
When Timer0 is in Counter mode, the synchronization
of the T0CKI input and the Timer0 register is
accomplished by sampling the prescaler output on the
Q2 and Q4 cycles of the internal phase clocks.
Therefore, the high and low periods of the external
clock source must meet the timing requirements as
shown in Section 15.0 “Electrical Specifications”.
CLRWDT
BANKSEL OPTION_REG
MOVLW
ANDWF
IORLW
MOVWF
Note:
b’11110000’
OPTION_REG,W ;prescaler bits
b’00000011’
OPTION_REG
TIMER0 INTERRUPT
The Timer0 interrupt cannot wake the
processor from Sleep since the timer is
frozen during Sleep.
USING TIMER0 WITH AN
EXTERNAL CLOCK
CHANGING PRESCALER
(WDT → TIMER0)
© 2007 Microchip Technology Inc.
;Clear WDT and
;prescaler
;
;Mask TMR0 select and
;Set prescale to 1:16
;