DEMOMPR083 Freescale Semiconductor, DEMOMPR083 Datasheet - Page 11

BOARD DEMO FOR MPR083 CTLR

DEMOMPR083

Manufacturer Part Number
DEMOMPR083
Description
BOARD DEMO FOR MPR083 CTLR
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of DEMOMPR083

Sensor Type
Touch, Capacitive
Sensing Range
8 Buttons/Keys
Interface
I²C
Voltage - Supply
1.8 V ~ 3.6 V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
MPR083
Operating Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Current
41 uA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Sensitivity
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
MPR083
Sensors
Freescale Semiconductor
3.5
The Touch Acquisition Sample Period Register is used to determine the electrode scan period of the system. The I
address of the Touch Acquisition Sample Period Register is 0x06.
Table 5. Rotary Configuration Register Field Descriptions
Table 6. Touch Acquisition Sample Register Field Description
Touch Acquisition Sample Period Register
Reset:
RRBE
RTBE
TASP
Field
Field
RSE
ACE
RE
7:0
W
7
4
3
2
0
R
7
0
Figure 15. Touch Acquisition Sample Period Register
= Unimplemented
Rotary Sounder Enable – The Rotary Sounder Enable bit controls if data is sent to
the sounder.
0 Disable – Click Feedback Off
1 Enable – Click Feedback On
Auto Calibration Enable – The Auto Calibration Enable bit enables or disables the
auto calibration function.
0 Disable
1 Enable
Rotary Release Buffer Enable – The Rotary Release Buffer Enable bit determines
whether or not data is logged in the FIFO when the rotary transitions from a touched
to untouched state.
0 Disable – No Release Data Logged
1 Enable – Release Data Logged
Rotary Touch Buffer Enable – The Rotary Touch Buffer Enable bit determines
whether or not data is logged in the FIFO any time a button is pressed.
0 Disable – Touches are not logged
1 Enable – Touches are logged
Rotary Enable – The Rotary Enable bit enables or disables the touch sensor. When
disabled, no touches are detected.
0 Disable – Touches not detected
1 Enable – Touches detected
Touch Acquisition Sample Period – The Touch Acquisition Sample Period Field
selects or reports the multiplication factor that is used to determine how often
electrodes are scanned. The resulting factor must be in the range 1 to 32. If the
value is outside of this range the TASP will be set to 00011111.
00000000 Encoding 0 – Sets the TASP multiplication factor to 1
~
00011111 Encoding 31 – Sets the TASP multiplication factor to 32.
6
0
5
0
4
0
TASP
Description
Description
3
0
2
0
1
0
0
1
2
C slave
MPR083
11