OKL-T/3-W12N-C Murata Power Solutions Inc, OKL-T/3-W12N-C Datasheet - Page 11

CONV DC/DC 15W 12VIN 3AOUT SMD

OKL-T/3-W12N-C

Manufacturer Part Number
OKL-T/3-W12N-C
Description
CONV DC/DC 15W 12VIN 3AOUT SMD
Manufacturer
Murata Power Solutions Inc
Series
Okami™ OKL-T/3-W12r
Type
Point of Load (POL) Non-Isolatedr
Datasheets

Specifications of OKL-T/3-W12N-C

Number Of Outputs
1
Output
0.59 ~ 5.5V
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
4.5 ~ 14V
Package / Case
12-SMD Module
1st Output
0.59 ~ 5.5 VDC @ 3A
Size / Dimension
0.48" L x 0.48" W x 0.25" H (12.2mm x 12.2mm x 6.4mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
EN, UL
Output Power
17 W
Input Voltage Range
4.5 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.591 V to 5.5 V
Output Current (channel 1)
3 A
Output Type
Adjustable Output DC/DC Converters
Output Voltage
0.591 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2072-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
OKL-T/3-W12N-C
Quantity:
2
OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=1.5A to 3A)
On/Off Enable Startup Delay (Vin=12V, Vout=1.2V, Iout=3A, Cload=0)
OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C
95
90
85
80
75
70
65
60
55
0
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div.
Trace 4=Enable In, Trace2=Vout
(Vout = 1.2V)
1
Load Curre nt (Amps)
2
V
V
V
IN
IN
IN
= 4.5V
= 12V
= 14V
www.murata-ps.com
3
Output Ripple and Noise (Vin=12V, Vout=1.2V, Iout=3A, Cload=0, ScopeBW=20MHz)
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=3A to 1.5A)
20
OKL-T/3-W12 Maximum Current Temperature Derating at Sea Level
Programmable Output 3-Amp iLGA SMT PoLs
30
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div.
28 Mar 2011
40
(V
OKL-T/3-W12 Series
IN
= 12V, V
Ambient Temperature (ºC)
50
MDC_OKL-T/3-W12 Series.A12 Page 11 of 18
OUT
= 1.2V)
60
Natural convection
email: sales@murata-ps.com
70
80
90

Related parts for OKL-T/3-W12N-C