Page 1
... The OKL-T/3-W12 series are miniature non-iso- lated Point-of-Load (PoL) DC/DC power converters for embedded applications. Featuring inspectable Land Grid Array (iLGA) format, the OKL-T/3-W12 measures only 0.48 x 0.48 x 0.244 inches max. (12.2 x 12.2 x 6.2 mm max.). The wide input range is 4 Volts DC. ...
Page 2
... Input Voltage Range 4.5-14Vdc Maximum Rated Output Current in Amps Model Number OKL-T/3-W12P-C OKL-T/3-W12N-C OKL2-T/3-W12P-C OKL2-T/3-W12N-C The manufacturing date code is four characters: First character – Last digit of manufacturing year, example 2009 Second character – Month code (1 through 9 and O through D) Third character – Day code (1 through 10=O and 11 through through Z) Fourth character – ...
Page 3
... Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page Function On/Off Control Ground V OUT Sense Trim Ground No Connection † ...
Page 4
... The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed +Vin. Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page OKL2-T/3-W12 9 ,227,000 4,860,000 ...
Page 5
... The converter will operate with no additional external capacitance if these conditions are met. www.murata-ps.com OKL-T/3-W12 Series APPLICATION NOTES email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page ...
Page 6
... CAUTION: These graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. www.murata-ps.com OKL-T/3-W12 Series COPPER STRIP SCOPE C1 C2 COPPER STRIP C1 = 1μF CERAMIC C2 = 10μF CERAMIC LOAD 2-3 INCHES (51-76mm) FROM MODULE email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page LOAD ...
Page 7
... Less than 3 ºC. per second Peak Temp. 235-260° C Reflow Zone Soaking Zone time above 217° C 45-75 sec 120 sec max Preheating Zone 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A11 Page 5.5 300 ...
Page 8
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 5V) 100 Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=5.0V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 9
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 3.3V) 100 Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=3.3V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 10
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 2.5V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=2.5V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 11
... Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=1.5A to 3A) Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=3A to 1.5A) Programmable Output 3-Amp iLGA SMT PoLs Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. www.murata-ps.com OKL-T/3-W12 Series email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page ...
Page 12
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 1.2V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=1.2V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 13
... Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=1.5A to 3A) Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=3A to 1.5A) Programmable Output 3-Amp iLGA SMT PoLs Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. www.murata-ps.com OKL-T/3-W12 Series email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page ...
Page 14
... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 0.591V Load C urre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=0.591V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=0.591V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 50 mV/div. Trace 4=Iout, 1A/div. ...
Page 15
... Pocket tape length before modules C Cover tape length before pocket tape www.murata-ps.com OKL-T/3-W12 Series Programmable Output 3-Amp iLGA SMT PoLs 7.40±0.1 0.40±0.05 Start of pocket tape C B Start of cover tape Length (mm) email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page 800 ±40 200 min. 240 ±40 ...