OKL-T/3-W12N-C Murata Power Solutions Inc, OKL-T/3-W12N-C Datasheet

CONV DC/DC 15W 12VIN 3AOUT SMD

OKL-T/3-W12N-C

Manufacturer Part Number
OKL-T/3-W12N-C
Description
CONV DC/DC 15W 12VIN 3AOUT SMD
Manufacturer
Murata Power Solutions Inc
Series
Okami™ OKL-T/3-W12r
Type
Point of Load (POL) Non-Isolatedr
Datasheets

Specifications of OKL-T/3-W12N-C

Number Of Outputs
1
Output
0.59 ~ 5.5V
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
4.5 ~ 14V
Package / Case
12-SMD Module
1st Output
0.59 ~ 5.5 VDC @ 3A
Size / Dimension
0.48" L x 0.48" W x 0.25" H (12.2mm x 12.2mm x 6.4mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
EN, UL
Output Power
17 W
Input Voltage Range
4.5 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.591 V to 5.5 V
Output Current (channel 1)
3 A
Output Type
Adjustable Output DC/DC Converters
Output Voltage
0.591 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2072-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
OKL-T/3-W12N-C
Quantity:
2
FEATURES
www.murata-ps.com
iLGA inspectable Land Grid Array
4.5-14Vdc input voltage range
Programmable output voltage from 0.591-5.5Vdc
Drives up to 200 μF ceramic capacitive loads
High power conversion effi ciency at 93%
Outstanding thermal derating performance
Short circuit and over current protection
On/Off control and Power Good signal
Optional Sequence/Tracking operation
(OKL2-T/3-W12 models)
Certifi ed to UL/EN/IEC 60950-1 safety, 2nd Edition
RoHS-6 hazardous substance compliance
www.murata-ps.com/rohs
Sequence/Tracking
External
DC
Power
Source
For full details go to
(OKL2 Models)
 
F1
Open = On
Closed = Off
Common
+Vin
(Positive
Typical unit
Control
On/Off
On/Off)
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifi cations.
Controller
PRODUCT OVERVIEW
lated Point-of-Load (PoL) DC/DC power converters
for embedded applications. Featuring inspectable
Land Grid Array (iLGA) format, the OKL-T/3-W12
measures only 0.48 x 0.48 x 0.244 inches max.
(12.2 x 12.2 x 6.2 mm max.).
The maximum output current is 3 Amps. Based
on fi xed-frequency synchronous buck converter
switching topology, the high power conversion
The OKL-T/3-W12 series are miniature non-iso-
The wide input range is 4.5 to 14 Volts DC.
www.murata-ps.com
Connection Diagram
Figure 1. OKL-T/3-W12
Contents
Description, Connection Diagram, Photograph
Ordering Guide, Product Label
Mechanical Specifi cations, Input/Output Pinout
Detailed Electrical Specifi cations
Output Voltage Adjustment, Application Notes
Performance Data and Oscillograms
Tape and Reel Information
Power Good
Reference and
Error Amplifier
Programmable Output 3-Amp iLGA SMT PoLs
01 Dec 2010
effi cient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, and
over-current protections.
OKL2-T/3-W12 models allows power sequencing of
PoL’s. These units are certifi ed to all standard UL/EN/
IEC 60950-1 safety certifi cations (2nd Edition) and
RoHS-6 hazardous substance compliance.
OKL-T/3-W12 Series
An optional sequence/tracking feature on
MDC_OKL-T/3-W12 Series.A11 Page 1 of 15
Common
Sense
+Vout
Trim
email: sales@murata-ps.com
Page
15
1
2
3
4
5
8

Related parts for OKL-T/3-W12N-C

OKL-T/3-W12N-C Summary of contents

Page 1

... The OKL-T/3-W12 series are miniature non-iso- lated Point-of-Load (PoL) DC/DC power converters for embedded applications. Featuring inspectable Land Grid Array (iLGA) format, the OKL-T/3-W12 measures only 0.48 x 0.48 x 0.244 inches max. (12.2 x 12.2 x 6.2 mm max.). The wide input range is 4 Volts DC. ...

Page 2

... Input Voltage Range 4.5-14Vdc Maximum Rated Output Current in Amps Model Number OKL-T/3-W12P-C OKL-T/3-W12N-C OKL2-T/3-W12P-C OKL2-T/3-W12N-C The manufacturing date code is four characters: First character – Last digit of manufacturing year, example 2009 Second character – Month code (1 through 9 and O through D) Third character – Day code (1 through 10=O and 11 through through Z) Fourth character – ...

Page 3

... Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page Function On/Off Control Ground V OUT Sense Trim Ground No Connection † ...

Page 4

... The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed +Vin. Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page OKL2-T/3-W12 9 ,227,000 4,860,000 ...

Page 5

... The converter will operate with no additional external capacitance if these conditions are met. www.murata-ps.com OKL-T/3-W12 Series APPLICATION NOTES email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page ...

Page 6

... CAUTION: These graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. www.murata-ps.com OKL-T/3-W12 Series COPPER STRIP SCOPE C1 C2 COPPER STRIP C1 = 1μF CERAMIC C2 = 10μF CERAMIC LOAD 2-3 INCHES (51-76mm) FROM MODULE email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page LOAD ...

Page 7

... Less than 3 ºC. per second Peak Temp. 235-260° C Reflow Zone Soaking Zone time above 217° C 45-75 sec 120 sec max Preheating Zone 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com MDC_OKL-T/3-W12 Series.A11 Page 5.5 300 ...

Page 8

... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 5V) 100 Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=5.0V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...

Page 9

... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 3.3V) 100 Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=3.3V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...

Page 10

... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 2.5V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=2.5V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...

Page 11

... Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=1.5A to 3A) Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=0, Iout=3A to 1.5A) Programmable Output 3-Amp iLGA SMT PoLs Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. www.murata-ps.com OKL-T/3-W12 Series email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page ...

Page 12

... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 1.2V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=1.2V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...

Page 13

... Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=1.5A to 3A) Step Load Transient Response (Vin=12V, Vout=1.0V, Cload=0, Iout=3A to 1.5A) Programmable Output 3-Amp iLGA SMT PoLs Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. www.murata-ps.com OKL-T/3-W12 Series email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page ...

Page 14

... OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C (Vout = 0.591V Load C urre nt (Amps) On/Off Enable Startup Delay (Vin=12V, Vout=0.591V, Iout=3A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=0.591V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 50 mV/div. Trace 4=Iout, 1A/div. ...

Page 15

... Pocket tape length before modules C Cover tape length before pocket tape www.murata-ps.com OKL-T/3-W12 Series Programmable Output 3-Amp iLGA SMT PoLs 7.40±0.1 0.40±0.05 Start of pocket tape C B Start of cover tape Length (mm) email: sales@murata-ps.com 01 Dec 2010 MDC_OKL-T/3-W12 Series.A11 Page 800 ±40 200 min. 240 ±40 ...

Related keywords