SE014S110 Lineage Power, SE014S110 Datasheet - Page 5

no-image

SE014S110

Manufacturer Part Number
SE014S110
Description
CONVERTER DC/DC E254110V 14W OUT
Manufacturer
Lineage Power
Series
SEr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of SE014S110

Output
110V
Number Of Outputs
1
Power (watts)
14W
Mounting Type
Through Hole
Voltage - Input
40 ~ 60V
Package / Case
6-DIP Module
1st Output
110 VDC @ 130mA
Size / Dimension
2.00" L x 2.00" W x 0.50" H (50.8mm x 50.8mm x 12.7mm)
Power (watts) - Rated
14W
Operating Temperature
-40°C ~ 85°C
Efficiency
82%
Approvals
CSA, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SE014S110
Manufacturer:
LUCENT
Quantity:
80
Data Sheet
January 2000
Test Configurations
Note: Input reflected-ripple current is measured with a simulated
Note: All measurements are taken at the module terminals. When
Figure 2. Output Voltage and Efficiency
Design Considerations
Output Capacitor
An external output capacitor is required for operation of
the power module. The output capacitor should be
mounted as close as possible to the module output
pins. Capacitor and ESR values are shown in the Out-
put Specifications table. The voltage rating of the out-
put capacitor should be at least 160 V.
Tyco Electronics Corp.
BATTERY
RESISTANCE
CONTACT
Figure 1. Input Reflected-Ripple Test Setup
SUPPLY
source impedance of 0.5 µH. Capacitor C
battery impedance. Voltage ripple is measured at the input ter-
minals of the module.
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
=
I
Measurement Test Setup
I
---------------------------------------------------- -
V
C
V
O
S
I
(+) V
(+) V
IMPEDANCE < 0.1
@ 20 C, 100 kHz
220 µF
V
V
I
I
(+)
(–)
O
I
(–)
0.5 µH
(–)
V
V
L
O
O
(+)
(–)
I
I
I
O
100
DISTRIBUTION LOSSES
33 µF
CONTACT AND
V
I
O
ripple
S
+
offsets possible
%
LOAD
V
V
I
I
(+)
(–)
8-652(C).a
8-653(C)
SE014S110 Power Module; dc-dc Converter:
Input Capacitor
The power module should be connected to a low
ac-impedance input source. Source impedances of
greater than 12 µH may affect the stability of the power
module. When the source impedance exceeds 12 µH,
mount a 47 µF electrolytic capacitor (ESR = 0.2
100 kHz, T
ule input pins.
An external input capacitor is not required if the input
source impedance is less than 12 µH.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL 1950 and CSA C22.2 No. 950-95.
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75 Vdc), for the module's output to be considered
meeting the requirements of safety extra-low voltage
(SELV), all of the following must be true:
Note: Do not ground either of the input pins of the
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a maxi-
mum 5 A normal-blow fuse in the ungrounded lead.
The input source is to be provided with reinforced
insulation from any other hazardous voltages, includ-
ing the ac mains.
One V
the input and output pins are to be kept floating.
The input pins of the module are not operator acces-
sible.
Another SELV reliability test is conducted on the
whole system, as required by the safety agencies, on
the combination of supply source and the subject
module to verify that under a single fault, hazardous
voltages do not appear at the module's output.
module without grounding one of the output
pins. This may allow a non-SELV voltage to
appear between the output pins and ground.
I
pin and one V
48 Vdc Input, 110 Vdc Output, 14 W
A
= 25 °C) as close as possible to the mod-
O
pin are to be grounded or both
at
5