SE014S110 Lineage Power, SE014S110 Datasheet - Page 2

no-image

SE014S110

Manufacturer Part Number
SE014S110
Description
CONVERTER DC/DC E254110V 14W OUT
Manufacturer
Lineage Power
Series
SEr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of SE014S110

Output
110V
Number Of Outputs
1
Power (watts)
14W
Mounting Type
Through Hole
Voltage - Input
40 ~ 60V
Package / Case
6-DIP Module
1st Output
110 VDC @ 130mA
Size / Dimension
2.00" L x 2.00" W x 0.50" H (50.8mm x 50.8mm x 12.7mm)
Power (watts) - Rated
14W
Operating Temperature
-40°C ~ 85°C
Efficiency
82%
Approvals
CSA, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SE014S110
Manufacturer:
LUCENT
Quantity:
80
SE014S110 Power Module; dc-dc Converter:
48 Vdc Input, 110 Vdc Output, 14 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
* In most applications, the external input capacitor is not required to operate the power module. See Design Considerations section.
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow fuse with a maximum rating of 5 A in series with the input (see Safety Con-
siderations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further
information.
2
Input Voltage
Operating Ambient Temperature
Storage Temperature
I/O Isolation Voltage:
Operating Input Voltage
Input Current (V
Inrush Transient
Input Ripple Voltage
(0.75 ms
(0.5 µH source; see Figure 1.):
Continuous
Transient (<1 second)
Without External Input Capacitor
With External Input Capacitor*
(C
I
= 47 µF; ESR = 0.2
–1
(150 ft./min.) above 70 °C)
I
= 0 V to 60 V)
Parameter
Parameter
at T
A
= 25 °C)
Symbol
Symbol
T
T
V
I
stg
A
I, max
I
V
i
2
t
I
Min
40
Min
–40
–40
0
Typ
100
48
1
1000
Max
100
500
63
85
Tyco Electronics Corp.
Max
0.8
0.2
60
January 2000
Data Sheet
Unit
Vdc
Vdc
Vdc
°C
°C
mVp-p
Vp-p
Unit
Vdc
A
A
2
s