MAX5952AEAX+ Maxim Integrated Products, MAX5952AEAX+ Datasheet - Page 32

IC PSE CNTRLR FOR POE 36-SSOP

MAX5952AEAX+

Manufacturer Part Number
MAX5952AEAX+
Description
IC PSE CNTRLR FOR POE 36-SSOP
Manufacturer
Maxim Integrated Products
Type
Power Over Ethernet Controller (PoE)r
Datasheet

Specifications of MAX5952AEAX+

Applications
Remote Peripherals (Industrial Controls, Cameras, Data Access)
Internal Switch(s)
No
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-BSOP (0.300", 7.5mm Width)
Product
Controllers & Switches
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.71 V
Power Dissipation
941 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Supply Current
4.8 mA
Input Voltage
60V
Digital Ic Case Style
SSOP
No. Of Pins
36
Uvlo
28.5V
Frequency
400kHz
Interface
I2C
Termination Type
SMD
Rohs Compliant
Yes
Filter Terminals
SMD
Controller Type
Power Over Ethernet PD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Setting DCD_EN_ to 1 enables the DC load disconnect
detection feature (Table 17). Setting ACD_EN_ to 1
enables the AC load disconnect feature. If enabled, the
load disconnect detection starts during power mode
High-Power, Quad, PSE Controller
for Power-Over-Ethernet
The MAX5952 uses two bits for each port to set the mode
of operation. Set the modes according to Table 16a.
A reset sets R12h = AAAAAAAA where A represents
the latched-in state of the AUTO input prior to the reset.
Table 16. Mode Register
Table 16a. Mode Status
Table 17. Load Disconnect Detection Enable Register
32
P4_M1
P4_M0
P3_M1
P3_M0
P2_M1
P2_M0
P1_M1
P1_M0
ACD_EN4
ACD_EN3
ACD_EN2
ACD_EN1
DCD_EN4
DCD_EN3
DCD_EN2
DCD_EN1
______________________________________________________________________________________
MODE
SYMBOL
SYMBOL
00
01
10
11
ADDRESS = 12h
ADDRESS = 13h
Shutdown
Manual
Semi-auto
Auto
BIT
BIT
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
DESCRIPTION
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
MODE[1] for port 4
MODE[0] for port 4
MODE[1] for port 3
MODE[0] for port 3
MODE[1] for port 2
MODE[0] for port 2
MODE[1] for port 1
MODE[0] for port 1
Enable AC disconnect detection on port 4
Enable AC disconnect detection on port 3
Enable AC disconnect detection on port 2
Enable AC disconnect detection on port 1
Enable DC disconnect detection on port 4
Enable DC disconnect detection on port 3
Enable DC disconnect detection on port 2
Enable DC disconnect detection on port 1
and after startup when the corresponding PGOOD_ bit
in register R10h (Table 14) goes high. A reset sets
R13h = 0000AAAA where A represents the latched-in
state of the AUTO input prior to the reset.
Use software to change the mode of operation.
Software resets of ports (RESET_P_ bit, Table 23) do
not affect the mode register.
DESCRIPTION
DESCRIPTION

Related parts for MAX5952AEAX+